Part Number Hot Search : 
LC040 KSC5031 P4KE6 G40338 KDR393S MC130 CCLH080 IS93C
Product Description
Full Text Search
 

To Download D31979-010 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  revision 1.7 intel order number: D31979-010 ii intel? server board s5000pal / s5000xal technical product specification intel order number: D31979-010 revision 1.7 february 2008 enterprise platforms and services division ? marketing
intel? server board s5000pal / s5000xal tps revision history revision 1.7 intel order number: D31979-010 iii revision history date revision number modifications april 2006 1.0 first external release. june 2006 1.1 updated theoretical memory bandwidth performance numbers. added platform control sections. august 2006 1.2 memory ras is now available. updated snoop filter section. updated figures #16 and #25. january 2007 1.3 updated table 44 bmc sensor. updated cmos clear and password reset usage procedures. updated regulatory tables. may 2007 1.4 removed platform control information that can be found in the intel ? s5000 server board family datasheet. august 2007 1.5 updated processor support section. october 2007 1.6 updated table 44 bmc sensor. february 2008 1.7 updated processor support section
disclaimers intel? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 iv disclaimers information in this document is pr ovided in connection with intel ? products. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. except as provided in intel's terms an d conditions of sale for such products , intel assumes no liability whatsoever, and intel disclaims any express or im plied warranty, rela ting to sale and/or use of intel products including liability or warranties relating to fitness for a particular purpose, merc hantability, or infringement of any patent, copyright or other intellectual property right. in tel products are not intended for use in medical, life saving, or life sustaining applications. intel may make changes to specifications and product descriptions at any time, without notice. designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." intel re serves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilitie s arising from future changes to them. the intel? server board s5000pal and the intel ? server board s5000xal may contain design defects or errors known as errata which may cause the product to deviate from published specifications. current characterized errata are available on request. intel corporation server baseboards support peripheral components and contain a number of high- density vlsi and power delivery components that need adequate airflow to cool. intel?s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. it is the responsib ility of the system integrator that chooses not to use intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. intel corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. intel, pentium, itanium, and xeon are trademarks or registered trademarks of intel corporation. *other brands and names may be claimed as the property of others. copyright ? intel corporation 2008.
intel? server board s5000pal / s5000xal tps table of contents revision 1.7 intel order number: D31979-010 v table of contents 1. introduction ................................................................................................................... ..... 12 1.1 chapter outline.............. ............... ............... ............ ............ ............. ............ ......... 12 1.2 server board use disclaimer ................................................................................ 12 2. product overview.......... ............... ............... ............... ............... ............... ............... ........... 13 2.1 intel? server board s5000pal / s5000xal feature set ..................................... 13 2.2 server board layout.............................................................................................. 14 2.2.1 connector and component locations . ............... ............... ............... ............ ......... 15 2.2.2 light guided diagnostic led locations ............. ............... ............... ............ ......... 17 2.2.3 external i/o connector locations.. .............. ............ ............ ............. ............ ......... 18 2.2.4 server board mechanical drawings .............. ............... ............... ............... ........... 19 3. functional architecture ........ ............... ............... ............... ............... ............ ............ ......... 24 3.1 intel ? 5000p and 5000x memory controller hubs (mch) ..................................... 25 3.1.1 system bus interface............................................................................................. 25 3.1.2 processor support ........... ............... ............... ............... ............... ............... ........... 25 3.1.3 memory sub-system .............................................................................................. 26 3.1.4 snoop filter (5000x mch only) ............................................................................. 32 3.2 esb-2 io controller ............................................................................................... 32 3.2.1 pci sub-system.......... ............... ............... ............... ............. ............ ............ ......... 33 3.2.2 serial ata support .......... ............... ............... ............... ............... ............... ........... 35 3.2.3 parallel ata (pata) support .... ............... ............... ............ ............. ............ ......... 36 3.2.4 usb 2.0 support....... ............... ............... ............... .............. ............. ............ ......... 36 3.3 video support ............. ............... ............... ............... ............ ............. ............ ......... 36 3.4 network interface controller (nic) ........................................................................ 38 3.4.1 intel ? i/o acceleration technology .... ............... ............... .............. ............... ......... 38 3.4.2 mac address definition......................................................................................... 38 3.5 super i/o ............................................................................................................... 39 4. platform management........................................................................................................ 42 5. connector / header locations and pin-outs.................................................................... 43 5.1 board connector information..... ............... ............... ............ ............. ............ ......... 43 5.2 power connectors ................................................................................................. 44 5.3 system management headers ....... ............... ............... ............... ............... ........... 45 5.3.1 intel ? remote management module (rmm) connect or .............. ............... ........... 45 5.3.2 intel ? rmm nic connector .................................................................................... 46 5.3.3 lcp/aux ipmb header ......................................................................................... 47 5.3.4 ipmb header ......................................................................................................... 47
table of contents intel? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 vi 5.4 riser card slots..................................................................................................... 47 5.5 ssi control panel connector........ ............... ............ ............ ............. ............ ......... 52 5.6 bridge board connector ............ ............... ............... ............ ............. ............ ......... 52 5.7 i/o connector pin-out definition ... ............... ............ ............. ............ ............ ......... 54 5.7.1 vga connector........... ............... ............... ............... ............ ............. ............ ......... 54 5.7.2 nic connectors ............... ............... ............... ............... ............... ............... ........... 54 5.7.3 ide connector ....................................................................................................... 55 5.7.4 intel ? i/o expansion module connector . .............. ............... ............. ............ ......... 55 5.7.5 sata connectors ............ ............... ............... ............... ............... ............... ........... 56 5.7.6 serial port connectors... ............... ............... ............ ............ ............. ............ ......... 57 5.7.7 keyboard and mouse connector ......... ............... ............... ............... ............ ......... 57 5.7.8 usb 2.0 connectors ........ ............... ............... ............... ............... ............... ........... 58 5.8 fan headers ............. ............... ............... ............... .............. ............. ............ ......... 59 6. jumper block settings ...................................................................................................... 60 6.1 recovery jumper blocks ....................................................................................... 60 6.1.1 cmos clear and password reset usage procedure ........................................... 61 6.1.2 bmc force update procedure ....... ............... ............... ............... ............... ........... 61 6.2 bios select jumper .............................................................................................. 62 6.3 external rj45 serial port jumper block................................................................ 63 7. light guided diagnostics..... ............... ............... ............... .............. ............. ............ ......... 64 7.1 5-volt standby led ............................................................................................... 64 7.2 system id led and system stat us led ............ ............... ............... ............ ......... 65 7.2.1 system status led ? bmc initialization ................................................................ 66 7.3 dimm fault leds .................................................................................................. 67 7.4 processor fault led.............................................................................................. 67 7.5 post code diagnostic leds ......... ............... ............ ............ ............. ............ ......... 68 8. power and environmental specifications........................................................................ 69 8.1 intel? server board s5000pal / s5000xal design specifications ..................... 69 8.2 server board power requirements ....................................................................... 70 8.2.1 processor power support...................................................................................... 70 8.2.2 power supply output requirement s ............. ............... ............... ............... ........... 71 8.2.3 turn on no load operation ......... ............... ............ ............ ............. ............ ......... 71 8.2.4 grounding .............. ............... ............... ............... ............... ............... ............ ......... 72 8.2.5 standby outputs .............. ............... ............... ............... ............... ............... ........... 72 8.2.6 remote sense ....................................................................................................... 72 8.2.7 voltage regulation .......... ............... ............... ............... ............... ............... ........... 72 8.2.8 dynamic loading ............. ............... ............... ............... ............... ............... ........... 73 8.2.9 capacitive loading .......... ............... ............... ............... ............... ............... ........... 73
intel? server board s5000pal / s5000xal tps table of contents revision 1.7 intel order number: D31979-010 vii 8.2.10 closed-loop stability....... ............... ............... ............... ............... ............... ........... 73 8.2.11 common mode noise ............................................................................................ 73 8.2.12 ripple / noise ........................................................................................................ 74 8.2.13 soft starting ........................................................................................................... 74 8.2.14 timing requirements............................................................................................. 74 8.2.15 residual voltage immunity in standby mode ..... ............... ............... ............ ......... 77 9. regulatory and certification information......................................................................... 78 9.1 product regulatory compliance ... ............... ............ ............. ............ ............ ......... 78 9.1.1 product safety & electromagnetic (emc) comp liance........... ............ ............. ...... 78 9.2 electromagnetic compatibility no tices ............... ............... ............... ............ ......... 79 9.2.1 fcc verification statement (usa) ........................................................................ 79 9.2.2 ices-003 (canada) ......... ............... ............... ............... ............... ............... ........... 79 9.2.3 europe (ce declaration of conformity) ............ ............... .............. ............... ......... 79 9.2.4 bsmi (taiwan) ....................................................................................................... 80 9.2.5 rrl (korea)........................................................................................................... 80 9.3 product ecology compliance.......... ............... ............... ............... ............... ........... 81 9.4 other markings ...................................................................................................... 82 appendix a: integration and usage tips................................................................................ 83 appendix b: bmc sensor tables ............................................................................................ 84 appendix c: post code diagnostic led decoder ............ ............... ............ ............. ......... 100 appendix d: post error messages and handling .............................................................. 104 appendix e: supported intel ? server chassis ............. ............... .............. ............... ............ 107 glossary............. .............. ............... ............... ............. ............ ............. ............ ............ ............ 110 reference documents ............................................................................................................ 113
list of figures intel? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 viii list of figures figure 1. components & connector location diagram ...... ............... ............... ............... ........... 16 figure 2. light guided diagnostic le d location diagram ........ ............... ............. ............ ......... 17 figure 3. intel? server board s5000pal / s5000xal atx i/o layout ............. ............... ......... 18 figure 4. intel? server board s5000pal / s5000 xal ? hole and component positions (1 of 2)19 figure 5. intel? server board s5000pal / s5000 xal ? hole and component positions (2 of 2)20 figure 6. intel? server board s5000pal / s5000xal ? restricted areas on side 1 ................ 21 figure 7. intel? server board s5000pal / s5000xal ? restricted areas on side 2 ................ 22 figure 8. intel? server board s5000pal / s5000xal - primary side duct and vr restrictions23 figure 9. server board functional block diagram....... ............... .............. ............. ............ ......... 24 figure 10. cek processor mounting .... ............... ............... ............... ............... ............... ........... 26 figure 11. memory layout ....................................................................................................... ... 27 figure 12. recommended minimum two dimm memory configuration ............ ............... ......... 29 figure 13. recommended four dimm configuration ....... ............ ............ ............. ............ ......... 30 figure 14. single branch mode sparing dimm configur ation .................................................... 31 figure 15. serial port configuration jumper location ... ............... ............ ............. ............ ......... 40 figure 16. smbus block diagram.............................................................................................. 42 figure 17. recovery jumper blocks (j1d1, j1d2, j1d3) ......................................................... 60 figure 18. bios select jumper (j3h1) ...................................................................................... 62 figure 19. external rj45 serial port configuration jumper ....................................................... 63 figure 20. 5v standby status led location ............... ............... ............... ............ ............ ......... 64 figure 21. system id led and system status led locations................................................... 65 figure 22. dimm fault led locations........................................................................................ 67 figure 23. processor fault led location ................................................................................... 67 figure 24. post code diagnostic led location ............. ............ ............ ............. ............ ......... 68 figure 25. power distribution block diagram ............................................................................. 70 figure 26. output voltage timing ....... ............... ............... ............... .............. ............... .............. 75 figure 27. turn on/off timing (power supply signals). ............... ............. ............ ............ ......... 76 figure 28. diagnostic led placement diagram ............ ............ ............. ............ ............. ......... 100 figure 29. 1u ? intel ? server chassis sr1500 overview ........................................................ 107 figure 30. 1u ? intel ? server chassis sr1550 overview ........................................................ 108 figure 31. 2u ? intel ? server chassis sr2500 overview ........................................................ 109
intel? server board s5000pal / s5000xal tps list of tables revision 1.7 intel order number: D31979-010 ix list of tables table 1. i 2 c addresses for memory module smb ..................................................................... 27 table 2. maximum 8 dimm system memory configur ation ? x8 single rank ........................... 28 table 3. maximum 8 dimm system memory configuration ? x4 dual rank .............................. 28 table 4. pci bus segment characteristics................................................................................. 33 table 5. video modes .......... ............... ............... ............... ............... ............ ............ ............. ...... 37 table 6. nic2 status led....................................................................................................... .... 38 table 7. serial a header pin-out ..... ............... ............... ............... ............... ............... ............... .39 table 8. rear serial b port adapter pin-out ............................................................................... 40 table 9. board connector matrix ................................................................................................ 43 table 10. power connector pin-out (j3k3) ................................................................................ 44 table 11. 12v power connector pin-out (j3k4)......................................................................... 44 table 12. power supply signal connector pin-out (j1k1) ........... ............ ............. ............ ......... 44 table 13. intel ? rmm connector pin-out (j1c5) . ............... ............... ............... ............... ........... 45 table 14. 30-pin intel ? rmm nic module connector pin-out (j1b 2) ............... ............... ........... 46 table 15. lpc/aux ipmb header pin-out (j1c2) ............ ............ ............ ............. ............ ......... 47 table 16. ipmb header pin-out (j1c3) ...................................................................................... 47 table 17. low-profile riser slot pin-out (j5b1).......................................................................... 47 table 18. full-height riser slot pin-out (j4f1)........................................................................... 48 table 19. front panel ssi standard 24-pin connector pin-out (j3h2) ............ ............... ........... 52 table 20. 120-pin bridgeboard connector pin-out (j4g1) ...... ............... ............... ............ ......... 52 table 21. vga connector pin-out (j6a1)................................................................................... 54 table 22. rj-45 10/100/1000 nic connec tor pin-out (ja8a1, ja8a2).... ............. ............ ......... 54 table 23. 44-pin ide connector pin-out (j3g1) ............ ............... ............ ............. ............ ......... 55 table 24. 50-pin intel ? i/o expansion module connector pin-out (j3b1)......... ............... ........... 56 table 25. sata connector pin-out (j1h1, j1g2, j1g1 , j1f2, j1e3) ............. ............... ........... 56 table 26. external rj-45 serial ?b? port pin-out (j9a2) ............................................................. 57 table 27. internal 9-pin serial ?a? header pin-out (j1b1) .................. ............... ............... ........... 57 table 28. stacked ps/2 keyboard and mouse port pin- out (j9a1) ....... ............... ............ ......... 57 table 29. external usb connector pin-out (j5a1, j6a2 )............... ............. ............ ............. ...... 58 table 30. internal usb connector pin-out (j1j1)....................................................................... 58 table 31. ssi fan connector pin-out (j9k1,j5k1,j 3k1,j3k2,j7a2,j7a1) ....... ............... ......... 59 table 32. recovery jumpers (j1d1, j1d2, j1d3) ..................................................................... 60 table 33: server board design specifications ........................................................................... 69 table 34. dual-core intel ? xeon ? processor 5000 sequence tdp guidelines per processor .. 70 table 35. 600w load ratings ............ ............... ............... .............. ............... ............... .............. 71
list of tables intel? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 x table 36: no load operating range ... ............... ............... .............. ............... ............... .............. 7 1 table 37. voltage regulation limits ..... ............... ............... ............... ............... ............... ........... 7 2 table 38. transient load requirements. ............. ............... ............... ............... ............... ........... 73 table 39. capacitive loading conditions .. ............... ............... ............... ............... ............ ......... 73 table 40. ripple and noise.............. ............... ............... ............... ............... ............... ............ .... 74 table 41. output voltage timing ................................................................................................ 75 table 42. turn on/off timing ................................................................................................... .. 76 table 43. bmc sensors.......................................................................................................... .... 86 table 44: post progress code led example ........................................................................ 100 table 45. diagnostic led post code decoder ........... ............. ............ ............ ............. ......... 101 table 46. post error messages and h andling............. ............. ............ ............ ............. ......... 104 table 47. post error beep codes ...... ............... ............... ............... ............... ............... ......... 106 table 48. bmc beep codes ............... ............... ............... ............... .............. ............... ............ 10 6
intel? server board s5000pal / s5000xal tps list of tables revision 1.7 intel order number: D31979-010 xi < this page intentionally left blank. >
introduction intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 12 1. introduction this technical product specification (tps) provides board specific information detailing the features, functionality, and high level architecture of the intel? server board s5000pal and intel ? server board s5000xal. the intel ? s5000 series chipsets server board family datasheet should also be referenced for more in depth detail of various board sub-systems including chipset, bios, system management, and system management software. in addition, design level information for specific sub-systems can be obtained by ordering the external product specifications (eps) or external design specifications (eds) for a given sub-system. eps and eds documents are not publicly available. they are only made available under nda with intel and must be ordered through your local intel representative. the intel? server board s5000pal/xal may contain design defects or errors known as errata which may cause the product to deviate from published specifications. refer to the intel? server board s5000pal/xal specification update for published errata. 1.1 chapter outline this document is divided into the following chapters ? chapter 1 ? introduction ? chapter 2 ? server board overview ? chapter 3 ? functional architecture ? chapter 4 ? platform management ? chapter 5 ? connector & header location and pin-out ? chapter 6 ? configuration jumpers ? chapter 7 ? light guided diagnostics ? chapter 8 ? power and environmental specifications ? chapter 9 ? regulatory and certification information ? appendix a ? integration and usage tips ? appendix b ? bmc sensor tables ? appendix c ? post code diagnostic led decoder ? appendix d ? post code errors ? appendix e ? supported intel ? server chassis 1.2 server board use disclaimer intel corporation server boards support add-in peripherals and contain a number of high-density vlsi and power delivery components that need adequate airflow to cool. intel ensures through its own chassis development and testing that when intel server building blocks are used together, the fully integrated system will meet the intended ther mal requirements of thes e components. it is th e responsibility of the system integrator who chooses not to use intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. intel corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non- operating limits.
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 13 2. product overview the intel? server board s5000pal and intel ? server board s5000xal are monolithic printed circuit boards with features that were designed to support the high-density 1u and 2u server markets. 2.1 intel? server board s500 0pal / s5000xal feature set feature description processors 771-pin lga sockets supporting 1 or 2 dual-core intel ? xeon ? processors 5000 sequence, with system bus speeds of 667 mhz, 1066 mhz, or 1333 mhz memory 8 keyed dimm slots supporting fully buffered dimm technology (fbdimm) memory. 240-pin ddr2-533 and ddr2-677 fbdimms must be used. chipset intel ? 5000 chipset family which includes the following components: intel ? 5000p memory controller hub or intel ? 5000x memory controller hub intel ? 6321esb i/o controller hub 1 note: intel will only make available an oem sku of this server board using the intel ? 5000x memory controller hub. on-board connectors/headers external connections: ? stacked ps/2* ports for keyboard and mouse ? rj45 serial b port ? two rj45 nic connectors for 10/100/1000 mb connections ? two usb 2.0 ports ? video connector internal connectors/headers: ? one usb port header, capable of providing two usb 2.0 ports ? one dh10 serial a header ? six sata ports via the esb-2 and integrated sw raid 0/1/10 support ? one 44pin (power + i/o) ata/100 connector for optical drive support ? one intel ? remote management module (intel ? rmm) connector (intel ? rmm use is optional) ? one intel ? i/o expansion module connector supporting: ? dual gb nic intel ? i/o expansion module (optional) ? external sas intel ? i/o expansion module (optional) ? infiniband* i/o expansion module (optional) ? ssi-compliant 24-pin control panel header ? ssi-compliant 24-pin main power connector, supporting the atx-12v standard on the first 20 pins ? 8-pin +12v processor power connector add-in pci, pci-x*, pci express* cards ? one low profile riser slot supporting 1u or 2u pcie* riser cards ? one full height riser slot supporting 1u or 2u pci-x* and pcie* riser cards on-board video ati* es1000 video controller with 16mb ddr sdram on-board hard drive controller ? six esb-2 sata ports. ? intel ? embedded server raid technology ii with sw raid levels 0/1/10. ? optional support for sw raid 5 with activation key. 2 lan two 10/100/1000 intel ? 82563eb phys supporting intel ? i/o acceleration technology system fans six 4-pin fan headers supporting two processor fans, and four system fans system management support for intel ? system management software 1 for the remainder of this document, the intel ? 6321esb i/o controller hub will be refferred to as esb-2. 2 onboard sata sw raid 5 support provided as a post-launch product feature.
product overview intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 14 2.2 server board layout
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 15 2.2.1 connector and component locations the following figure shows the board layout of the server board. each connector and major component is identified by a number or letter, and a description is given below the figure. tp02071 m n o l j k v u s t r w q p pp mm ll kk ii hh gg ff ee dd cc bb aa z y x b a e d f h g c i nn oo qq jj
product overview intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 16 description description a bios bank select jumper v system fan #2 header b intel ? esb-2 io controller hub w cpu power connector c io module option connector x main power connector d post code diagnostic leds y battery e intel ? adaptive slot ? full height z power supply management connector f pci express* riser slot ? low profil e aa dual port usb 2.0 header g system identification led - blue bb system fan #1 header h external io connectors cc ssi 24-pin control panel header i status led ? green / amber dd sata 0 j serial ?b? port configuration jumper ee sata 1 k system fan #4 header ff sata 2 l system fan #3 header gg sata 3 m fbdimm slots hh sata 4 n intel ? 5000p memory controller hub (mch) or intel ? 5000x memory controller hub (mch) ii sata 5 o cpu #1 connector jj sata sw raid 5 activation key connector p cpu #2 connector kk intel ? remote management module (rmm) connector q cpu #1 fan header ll system recovery jumper block r voltage regulator heat sink mm chassis intrusion switch header s cpu #2 fan header nn 3-pin ipmb header t bridge board connector oo intel ? local control panel header u ata-100 optical drive connector (power+io) pp serial ?a? header qq intel ? rmm nic connector figure 1. components & connector location diagram
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 17 2.2.2 light guided diagnostic led locations tp02317 s r q b a c f g e l ijk no mp d description description a post code diagnostic leds e cpu fault led b system identification led ? blue f cpu fault led c system status led ? green / amber g 5-volt stand-by present led d dimm fault leds figure 2. light guided diagnostic led location diagram
product overview intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 18 2.2.3 external i/o connector locations the drawing below shows the layout of the rear i/o components for the server board. tp02296 a f c d e g h b a ps/2 mouse e nic port 2 (1 gb) b ps/2 keyboard f video c serial port b g usb port 1 d nic port 1 (1 gb) h usb port 2 figure 3. intel? server board s5000pal / s5000xal atx i/o layout
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 19 2.2.4 server board mechanical drawings tp02316 4 x 187.93 [7.399] 2 x 0.00 [0.000] 11.02 [0.434] 11.91 [0.469] 16.76 [0.660] 33.91 [1.335] 44.89 [1.767] 82.80 [3.260] 2 x 124.46 [4.900] 288.29 [11.350] 2 x 86.89 [3.421] 16.51 [0.650] 2 x 0.00 [0.000] 15.24 [0.600] 21.59 [0.850] 45.59 [1.795] 227.33 [8.950] 3 x 312.42 [12.300] 320.04 [12.600] 127.43 [5.017] 62.66 [2.467] 67.31 [2.650] 2 x 49.35 [1.943] 10.16 [0.400] 0.91 [0.036] 2 x 101.60 [4.000] 22.86 [0.900] 0.16 [0.006] 9 x ? 0.125 [3.18] typ. lotes b2515bb2m 6012a0019603 5.08 [0.200] 9.65 [0.380] 2 x 59.69 [2.350] 124.46 [4.900] 2 x 141.25 [5.561] 38.10 [1.500] typ. 2 x 223.80 [8.811] 2 x 281.94 [11.100] 81.28 [3.200] typ. 2 x 3.28 [0.129] 55.35 [2.179] 8 x ? 10.16 [0.400] 7 x ? 3.96 [0.156] 124.26 [4.892] molex 22-44-7031 6012a0099701-hdr4p molex 22-44-7031 6012a0099701 228.60 [9.000] lotes b2515bb2m 6012a0019603 152.40 [6.000] 6 x betterment btm-pp02.2f1611.007x 6012b0018302 amp 794108-1 6012a0022801 molex 3930-0080 6012a0022801 118.11 [4.650] 196.85 [7.750] 5 x ? 8.00 [0.315] silkscreen on secondary side for spacer lotes aaa-pci-033-k02 6012b0051002 lotes b4l60bb2l 6012a0105401 amp 177983-5 6012a0103201 molex 43202-8927 6026a0027801 molex 877715-3205 6012a0100101 fci 10027747-114101 6012a0105001 figure 4. intel? server board s5000pal / s5000xal ? hole and component positions (1 of 2)
product overview intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 20 tp02292 143.00 [5.630] 231.89 [9.130] 243.83 [9.600] 265.41 [10.449] 297.84 [11.726] 308.74 [12.155] 214.12 [8.430] 196.33 [7.730] 178.56 [7.030] 160.77 [6.330] 11.96 [0.471] 3.45 [0.136] 10.16 [0.400] 0.00 [0.000] 30.91 [1.217] 49.68 [1.956] 19.76 [0.778] 35.05 [1.380] 62.99 [2.480] 76.45 [3.010] 67.39 [2.653] 0.00 [0.000] 224.21 [8.827] 2.67 [0.105] 6.27 [0.247] 35.28 [1.389] 8 x 40.39 [1.590] 7 x 10.67 [0.420] 244.27 [9.617] 263.14 [10.360] 278.38 [10.960] 280.71 [11.052] 175.03 [6.891] 200.13 [7.879] 205.97 [8.109] 158.80 [6.252] 141.78 [5.582] 87.88 [3.460] 9.32 [0.367] 56.84 [2.238] 5.21 [0.205] 127.20 [5.008] 80.14 [3.155] 16.51 [0.650] 106.93 [4.210] 104.39 [4.110] 94.23 [3.710] 100.58 [3.960] 2 x 1.83 [0.072] 5 x 6.99 [0.275] 8.64 [0.340] 3.35 [0.132] 298.51 [11.752] 309.042 [12.167] 52.98 [2.086] 12.66 [0.498] 74.78 [2.944] 83.31 [3.280] 76.96 [3.030] 96.25 [3.789] 104.39 [4.110] 280.21 [11.032] 2 x 11.93 [0.470] 6 x 12.83 [0.505] 211.02 [8.308] 174.17 [6.857] 214.63 [8.450] 230.38 [9.070] 1st pin 1st pin r1.52 [0.060] 119.59 [4.708] 119.16 [4.692] 1st pin 86.11 [3.390] 3 x 13.59 [0.535] 2 x 12.33 [0.485] 12.27 [0.483] 9.07 [0.357] figure 5. intel? server board s5000pal / s5000xal ? hole and component positions (2 of 2)
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 21 tp02293 h < 10mm [0.394"] pci bkt drop down 170.64 [6.718] 184.12 [7.249] 273.02 [10.749] ref only h < 7 mm [0.275"] under heat sink 102.77 [4.046] 46.76 [1.841] 18.97 [0.747] 0.18 [0.007] 10.80 [0.425] h < 3mm [0.118"] pci bkt drop down 198.02 [7.796] 207.98 [8.188] 267.51 [10.532] 288.29 [11.350] h < 12.7 mm [0.499"] under lp pci option card h < 5 mm [0.196"] pci bkt drop down 3.81 [0.150] h < 11.65 mm [0.459"] under rear panel tab h < 30 mm [1.181"] pci bkt drop down no components allowed for retention pins h < 3.5 mm [0.138"] for three boards 9 x no components 5.0 dia. on top no components 3.5 dia. on bottom h < 12.4 mm [0.488"] under riser pcie conn. h < 26 mm [1.023"] under riser pci-x conn. h < 11.8 mm [0.465"] under riser card h < 15.2 mm [0.600"] under fh pci option card 264.97 [10.432] 316.00 [12.441] 320.04 [12.600] 234.75 [9.242] 169.98 [6.692] 130.00 [5.118] 10.16 [0.400] 2 x 5.08 [0.200] 3 x 5.08 [0.200] 0.00 [0.000] 2 x 3.07 [0.121] 21.23 [0.836] 28.17 [1.109] 41.96 [1.652] 53.34 [2.100] 60.15 [2.368] 177.47 [6.987] 180.92 [7.123] 188.72 [7.430] 0.00 [0.000] 0.76 [0.030] 13.18 [0.519] 9.27 [0.365] 3.28 [0.129] 16.51 [0.650] 57.89 [2.279] 96.98 [3.818] 98.88 [3.893] 101.90 [4.012] 109.40 [4.307] 120.85 [4.758] 125.27 [4.932] 129.69 [5.106] 134.62 [5.300] 137.72 [5.422] ref only h < 11 mm [0.433"] under heat sink 89.36 [3.518] 9.70 [0.382] 94.41 [3.717] 96.57 [3.802] 111.84 [4.403] 120.93 [4.761] 199.67 [7.861] 203.48 [8.011] 282.22 [11.111] h < 9.5 mm [0.374"] under bridge board 4 x 7.62 [0.300] figure 6. intel? server board s5000pal / s5000xal ? restricted areas on side 1
product overview intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 22 tp02294 0.00 [0.000] 16.51 [0.650] 288.29 [11.350] 0.00 [0.000] 320.04 [12.600] 10.16 [0.400] 10.13 [0.399] 257.73 [10.147] 2 x 5.00 [0.197] h < 1.47 mm [0.058"] typ. 3 x 3.99 [0.157] 3.00 [0.118] ? 2.000 [50.8 mm] typ. 15.24 [0.600] typ. 5.08 [0.200] typ. 20.32 [0.800] typ. limited height 1.27 mm [0.05"] on side 2 h < 2 mm [0.078] 7.52 [0.296] 123.47 [4.861] 184.40 [7.260] 136.14 [5.360] 266.95 [10.510] 218.72 [8.611] 197.10 [7.760] 205.99 [8.110] 279.68 [11.011] 200.03 [7.875] 4 x 4.45 [0.175] 180.34 [7.100] 276.86 [10.900] limited height 1.27 mm [0.05"] on side 2, dia. 29.5 mm [1.160"] backside spring area. no motherboard component placement allowed. no components or surface layer traces in this zone. ? 29.46 [1.160] typ. 0.200" [5.08 mm max] keep in for 2u and above platforms. 0.100" [2.54 mm max] keep in for 1u platforms on side 2. 3 ground pad on side 2 figure 7. intel? server board s5000pal / s5000xal ? restricted areas on side 2
intel ? server board s5000pal / s5000xal tps product overview revision 1.7 intel order number: D31979-010 23 tp02295 256.54 [10.100] 2 x 173.99 [6.850] h < 10.0 mm [0.394"] under duct h < 0.8 mm [0.310"] under vr h < 1.5 mm [0.059"] under vr 143.51 [5.650] no components allowed for duct 0.00 [0.000] 10.16 [0.400] 182.83 [7.198] 3 x 274.32 [10.800] 298.51 [11.753] 0.00 [0.000] 16.51 [0.650] 113.13 [4.454] 199.21 [7.843] 285.75 [11.250] 109.86 [4.325] 125.78 [4.952] 5.08 [0.200] 5.52 [0.217] 4.83 [0.190] 2 x 77.22 [3.040] 6.35 [0.250] 11.69 [0.460] no components allowed h < 27 mm [1.063"] under duct figure 8. intel? server board s5000pal / s5000xal - primary side duct and vr restrictions
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 24 3. functional architecture the architecture and design of the intel? server board s5000pal / s5000xal is based on the intel ? 5000 chipset family. the chipset is designed for systems based on the dual-core intel ? xeon ? processor 5000 sequence with system bus speeds of 667 mhz, 1066 mhz, and 1333 mhz. the chipset is made up of two main components: the memory controller hub (mch) for the host bridge and the esb- 2 i/o controller hub for the i/o subsystem. this chapter provides a high-level description of the functionality associated with each chipset component and the architectural blocks that make up this server board. for more in depth detail of the functionality for each of the chipset components and each of the functional architecture blocks, see the intel ? s5000 server board family datasheet. figure 9. server board functional block diagram note: the diagram above uses the intel ? 5000p mch as a general reference designator for both mch components supported on this server board.
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 25 3.1 intel ? 5000p and 5000x memory controller hubs (mch) this section will describe the general functionality of the memory controller hub as it is implemented on this server board. depending on the version of the server board in use, it may support either the intel ? 5000p mch or the intel ? 5000x mch. features that are unique to a particular mch will be so referenced. the memory controller hub (mch) is a single 1432 pin fcbga package which includes the following core platform functions: ? system bus interface for the processor sub-system ? memory controller ? pci express* ports including the enterprise south bridge interface (esi) ? fbd thermal management ? smbus interface additional information about mch functionality can be obtained from the intel ? s5000 series chipsets server board family datasheet, the intel ? 5000p memory controller hub external design specification (yellow cover), or the intel ? 5000x memory controller hub external design specification (yellow cover). note: yellow cover documents can only be obtained under nda with intel and ordered through an intel representative. 3.1.1 system bus interface the mch is configured for symmetric multi-processing across two independent front side bus interfaces that connect to the dual-core intel ? xeon ? processors 5000 sequence. each front side bus on the mch uses a 64-bit wide 1066 or 1333 mhz data bus. the 1333 mhz data bus is capable of transferring data at up to 10.66 gb/s. the mch supports a 36-bit wide address bus, capable of addressing up to 64 gb of memory. the mch is the priority agent for both fr ont side bus interfaces, and is optimized for one processor on each bus. 3.1.2 processor support the server board supports the following processors: ? one or two dual-core intel ? xeon ? processors 5000 or 5100 sequence with a 677-, 1066-, or 1333-mhz front side bus. ? up to two quad-core intel ? xeon ? processors 5300 sequence with a 1066- or 1333-mhz front side bus. ? up to two 45nm 2p dual-core intel ? xeon ? processors. systems based on s5000palr or s5000xalr only. ? up to two 45nm next generation quad-core intel ? xeon ? processors. systems based on s5000palr or s5000xalr only. previous generations of the intel ? xeon ? processor are not supported on the server board. see http://support.intel.com/support /motherboards/server/s5000pal/ for a complete updated list of supported processors. ( http://support.intel.com/support/motherboards/server/sb/cs-022346.htm/ is sub-directory of above s5000pal url that reflects supported processor list) note: only dual-core intel ? xeon ? processors 5000 sequence, that support system bus speeds of 667 mhz, 1066 mhz, and1333 mhz are supported on this server board.
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 26 3.1.2.1 processor population rules when two processors are installed, both must be of identical revision, core voltage, and bus/core speed. mixed processor steppings is supported. however, the stepping of one processor cannot be greater than one stepping back of the other. when only one processor is installed, it must be in the socket labeled cpu1. the other socket must be empty. the board is designed to provide up to 130a of current per processor. processors with higher current requirements are not supported. no terminator is required in the second processor socket when using a single processor configuration. 3.1.2.2 common enabling kit (cek) design support the server board complies with intel?s common enabling kit (cek) processor mounting and heat sink retention solution. the server board ships with a cek spring snapped onto the underside of the server board, beneath each processor socket. the heat sink attaches to the cek, over the top of the processor and the thermal interface material (tim). see the figure below for the stacking order of the chassis, cek spring, server board, tim, and heat sink. the cek spring is removable, allowing for the use of non-intel heat sink retention solutions. note: the processor heat sink and cek spring shown in the following diagram are for reference purposes only. the actual processor heat sink and cek solutions compatible with this generation server board may be of a different design. heatsink assembly thermal interface material (tim) server board cek spring chassis figure 10. cek processor mounting 3.1.3 memory sub-system on the intel? server board s5000pal / s5000xal, the mch provides four channels of fully buffered dimm (fb-dimm) memory. each channel can support up to 2 dual ranked fb-dimm ddr2 dimms. fb- dimm memory channels are organized in to two branches for support of raid 1 (mirroring). the mch can support up to 8 dimms or a maximum memory size of 32 gb physical memory in non-mirrored mode and 16 gb physical memory in a m irrored configuration. th e read bandwidth for each fb-dimm channel is 4.25 gb/s for ddr2 533 fb-dimm memory which gives a total read bandwidth of 17 gb/s for four fb- dimm channels. thus, this provides 8.5 gb/s of write memory bandwidth for four fb-dimm channels. the read bandwidth for each fb-dimm channel is 5.3gb/s for ddr2 667 fb-dimm memory which gives
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 27 a total read bandwidth of 21gb/s for four fb-dimm channels. thus, this provides 10.7 gb/s of write memory bandwidth for four fb-dimm channels. the total bandwidth is based on read bandwidth thus the total bandwidth is 17 gb/s for 533 and 21.0 gb/s for 667. on the intel? server board s5000pal / s5000xal, a pair of channels becomes a branch where branch 0 consists of channels a and b, and branch 1 consists of channels c and d. fbd memory channels are organized into two branches for support of raid 1(mirroring). tp02299 dimm d2 dimm d1 dimm c2 dimm c1 dimm b2 dimm b1 dimm a2 dimm a1 branch 0 mch channel a channel b channel d channel c branch 1 figure 11. memory layout to boot the system, the system bios on the server board uses a dedicated i 2 c bus to retrieve dimm information needed to program the mch memory registers. the following table provides the i 2 c addresses for each dimm slot. table 1. i 2 c addresses for memory module smb device address dimm a1 0xa0 dimm a2 0xa2 dimm b1 0xa0 dimm b2 0xa2 dimm c1 0xa0 dimm c2 0xa2 dimm d1 0xa0 dimm d2 0xa2 3.1.3.1 memory rasum features i the mch supports several memory rasum (reliability, availability, serviceability, usability, and manageability) features. thes e features include the intel ? x4 single device data correction (intel ? x4 sddc) for memory error detection and correction, memory scrubbing, retry on correctable errors, memory built in self test, dimm sparing, and memory mirroring. see the intel ? s5000 series chipsets server board family datasheet for more information describing these features. 3.1.3.2 supported memory the server board supports up to eight ddr2-533 or ddr2-667 fully buffered dimms (fbd memory). the following tables show the maximum memory configurations supported using the specified memory technology.
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 28 table 2. maximum 8 dimm system memory configuration ? x8 single rank dram technology x8 single rank maximum capacity mirrored mode maximum capacity non-mirrored mode 256 mb 1 gb 2 gb 512 mb 2 gb 4 gb 1024 mb 4 gb 8 gb 2048 mb 8 gb 16 gb table 3. maximum 8 dimm system memory configuration ? x4 dual rank dram technology x4 dual rank maximum capacity mirrored mode maximum capacity non-mirrored mode 256 mb 4 gb 8 gb 512 mb 8 gb 16 gb 1024 mb 16 gb 32 gb 2048 mb 16 gb 32 gb note : ddr2 dimms that are not fully buffered are not supported on this server board. see the intel? server board s5000pal / s5000xal tested memory list for a complete list of supported memory for this server board. 3.1.3.3 dimm population rules and supported dimm configurations dimm population rules depend on the operating mode of the memory controller, which is determined by the number of dimms installed. dimms must be populated in pairs. dimm pairs are populated in the following dimm slot order: a1 & b1, c1 & d1, a2 & b2, c2 & d2. dimms within a given pair must be identical with respect to size, speed, and organization. however, dimm capacities can be different between different dimm pairs. for example, a valid mixed dimm configuration may have 512mb dimms installed in dimm slots a1 & b1, and 1gb dimms installed in dimm slots c1 & d1. intel supported dimm configurations for this server board are shown in the following table. supported and validated configuration : slot is populated supported but not validated configuration : slot is populated slot is not populated mirroring: y = yes. indicates that configuration supports memory mirroring. sparing: y(x) = yes. indicates that configuration supports memory sparing. where x = 0 : sparing supported on branch0 only 1 : sparing supported on branch1 only 0,1 : sparing supported on both branches branch 0 branch 1 channel a channel b channel c channel d dimm_a1 dimm_a2 dimm_b1 dimm b2 dimm c1 dimm c2 dimm d1 dimm d2 mirroring possible sparing possible
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 29 y (0) y y (0) y y (0, 1) notes: - single channel mode is only tested and supported with a 512mb x8 fbdimm installed in dimm slot a1. - the supported memory configurations must meet population rules defined above. - for best performance, the number of dimms installed should be balanced across both memory branches. for example: a four dimm configuration will perform better than a two dimm configuration and should be installed in dimm slots a1, b1, c1, and d1. an eight dimm configuration will perform better then a six dimm configuration. - although mixed dimm capacities between channels is supported, intel does not validate dimms in mixed dimm configurations. 3.1.3.3.1 minimum non-mirrored mode configuration the server board is capable of supporting a minimum of one dimm installed. however, for system performance reasons, intel?s recommendation is that at least 2 dimms be installed. the following diagram shows the recommended minimum dimm memory configuration. populated dimm slots are shown in grey . tp02300 dimm d2 dimm d1 dimm c2 dimm c1 dimm b2 dimm b1 dimm a2 dimm a1 branch 0 mch channel a channel b channel d channel c branch 1 figure 12. recommended minimum two dimm memory configuration note: the server board supports sing le dimm mode operation. intel w ill only validate and support this configuration with a single 512mb x8 fbdimm installed in dimm slot a1.
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 30 3.1.3.4 non-mirrored mode memory upgrades the minimum memory upgrade increment is two dimms per branch. the dimms must cover the same slot position on both channels. dimms pairs must be identical with respect to size, speed, and organization. dimms that cover adjacent slot positions do not need to be identical. when adding two dimms to the configuration shown in figure 12, the dimms should be populated in dimm slots c1 and d1 as shown in the following diagram. populated dimm slots are shown in grey . tp02301 dimm d2 dimm d1 dimm c2 dimm c1 dimm b2 dimm b1 dimm a2 dimm a1 branch 0 mch channel a channel b channel d channel c branch 1 figure 13. recommended four dimm configuration functionally, dimm slots a2 and b2 could also have been populated instead of dimm slots c1 and d1. however, your system will not ac hieve equivalent performance. fi gure 13 shows the supported dimm configuration that is recommended because it allows both memory branches from the mch to operate independently and simultaneously. fbd bandwidth is doubled when both branches operate in parallel. 3.1.3.4.1 mirrored mode memory configuration when operating in mirrored mode, both branches operate in lock step. in mirrored mode, branch 1 contains a replicate copy of the data in branch 0. the minimum dimm configuration to support memory mirroring is four dimms, populated as shown in figure 13 above. all four dimms must be identical with respect to size, speed, and organization. to upgrade a four dimm mirrored memory configuration, four additional dimms must be added to the system. all four dimms in the second set must be identical to the first with the exception of speed. the mch will adjust to the lowest speed dimm.
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 31 3.1.3.4.2 dimm sparing mode memory configuration the mch provides dimm spa ring capabilities. sparing is a ras feat ure that involves configuring a dimm to be placed in reserve so it can be use to replace a dimm that fails. dimm sparing occurs within a given bank of memory and is not supported across branches. there are two supported memory sparing configurations. 3.1.3.4.2.1 single branch mode sparing channel a channel b channel c channel d branch 0 branch 1 intel? 5000p/5000x memory controller hub slot 1 slot 2 dimm_c2 dimm_c1 dimm_d2 dimm_d1 dimm_a1 dimm_a2 dimm_b1 dimm_b2 figure 14. single branch mode sparing dimm configuration ? dimm_a1 and dimm_b1 must be identical in organization, size and speed. ? dimm_a2 and dimm_b2 must be identical in organization, size and speed. ? dimm_a1 and dimm_a2 need not be identical in organization, size and speed. ? dimm_b1 and dimm_b2 need not be identical in organization, size and speed. ? sparing should be enabled in bios setup. ? bios will configure rank sparing mode. ? the larger of the pairs {dimm_a1, dimm_b1} and {dimm_a2, dimm_b2} will be selected as the spare pair unit.
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 32 3.1.3.4.2.2 dual branch mode sparing dual branch mode sparing requires that all eight dimm slots be populated and must comply with the following population rules. ? dimm_a1 and dimm_b1 must be identical in organization, size and speed. ? dimm_a2 and dimm_b2 must be identical in organization, size and speed. ? dimm_c1 and dimm_d1 must be identical in organization, size and speed. ? dimm_c2 and dimm_d2 must be identical in organization, size and speed. ? dimm_a1 and dimm_a2 need not be identical in organization, size and speed. ? dimm_b1 and dimm_b2 need not be identical in organization, size and speed. ? dimm_c1 and dimm_c2 need not be identical in organization, size and speed. ? dimm_d1 and dimm_d2 need not be identical in organization, size and speed. ? sparing should be enabled in bios setup. ? bios will configure rank sparing mode. ? the larger of the pairs {dimm_a1, dimm_b1} and {dimm_a2, dimm_b2} and {dimm_c1, dimm_d1} and {dimm_c2, dimm_d2} will be selected as the spare pair units. 3.1.4 snoop filter (5000x mch only) the 5000x version of the mch includes a snoop filter. depending on the application of the server, this feature can be used to enhance the performance of the server by eliminating unnecessary traffic on the system bus. by removing the excess traffic from the snooped bus, the full bandwidth is available for other operations. 3.2 esb-2 io controller the esb-2 is a multi-function device that provides four distinct functions: an io controller, a pci-x* bridge, a gigabit ethernet controller, and a baseboard management controller (bmc). each function within the esb-2 has its own set of configuration registers. once configured, each appears to the system as a distinct hardware controller. a primary role of the esb-2 is to provide the gateway to all pc-compatible i/o devices and features. the server board uses the following esb-2 features: ? pci-x* bus interface ? six channel sata interface w/sata busy led control ? dual gbe mac ? baseboard management controller (bmc) ? single ata interface, with ultra dma 100 capability ? universal serial bus 2.0 (usb) interface ? removable media drives ? lpc bus interface ? pc-compatible timer/counter and dma controllers ? apic and 8259 interrupt controller ? power management ? system rtc ? general purpose i/o
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 33 this section describes the function of most of the listed features as they pertain to this server board. for more detail information, see the intel ? s5000 series chipsets server board family datasheet or the intel ? enterprise south bridge-2 external design specification (yellow cover) 3.2.1 pci sub-system the primary i/o buses for the server board are pci, pci express*, and pci-x*, with six independent pci bus segments. the pci buses comply with the pci local bus specification , revision 2.3. the table below lists the characteristics of the pci bus segments. details about each bus segment follow the table. table 4. pci bus segment characteristics pci bus segment voltage width speed type on-board device support pci32 esb-2 3.3v 32 bit 33mhz pci used internally for video controller pxa esb-2 3.3v/5.0v 64 bit 133mhz pci-x* full height riser slot, up to three slots on riser card pe1 esb-2 pcie* port2 3.3v x4 10gb/s pcie* used for intel chassis for mid-plane iop pe2 esb-2 pcie port3 3.3v x4 10gb/s pcie mezzanine connector for intel ? i/o expansion module pe4, pe5 bnb pcie ports 4,5 3.3v x8 20gb/s pcie low profile riser slot, up to two x4 slots on 2u riser, or one x8 slot on 1u riser. pe6, pe7 bnb pcie ports 6,7 3.3v x8 20gb/s pcie full height riser slot, up to two x4 slots on riser or one x8 3.2.1.1 pci32: 32-bit, 33-mhz pci bus segment all 32-bit, 33-mhz pci i/o is directed through the esb-2 ich6. the 32-bit, 33-mhz pci segment created by the esb-2-ich6 is known as the pci32 segment. the pci32 segment supports the following embedded devices: ? 2d graphics accelerator: ati* es1000 video controller 3.2.1.2 pxa: 64-bit, 133mhz pci-x* bus segment one 64-bit pci-x* bus segment is directed through the esb-2 ich6. this pci-x segment, pxa, can support up to three add-in cards on a riser card plugged into the full height riser card slot (j4f1). 3.2.1.3 pe1: one x4 pci express* bus segment one x4 pci express* bus segment is directed through the esb-2. this pci express segment, pe1, supports the optional active sas midplane iop as used in supported intel chassis for this server board. 3.2.1.4 pe2: one x4 pci express* bus segment one x4 pci express* bus segment is directed through the esb-2. this pci express segment, pe2, supports one x4 pci express segment to the proprietary intel ? i/o expansion module mezzanine connector (j3b1).
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 34 3.2.1.5 pe4, pe5: two x4 pci express* bus segments two x4 pci express* bus segments are directed through the mch. these pci express segments, pe4 and pe5, support one x8 or two x4 pci express segments to the low profile riser slot (j5b1). 3.2.1.6 pe6, pe7: two x4 pci express* bus segments two x4 pci express* bus segments are directed through the mch. these pci express segments, pe6 and pe7, support one x8 or two x4 pci express segments to the full height riser slot (j4f1). 3.2.1.7 pci riser slots the server board has two riser slots capable of supporting riser cards for both 1u and 2u system configurations. because of board placement resulting in different pin orientations, and expanded technology support associated with the full-height riser, the riser slots are not the same and require different riser cards. the low profile riser slot (j5b1) utilizes a 98-pin connec tor. it is capable of supp orting one x8 (1u) or two x4 (2u) low profile pci express* add-in cards. the x8 pci express* bus can support bus speeds of up to 20 gb/s. the following table provides the supported bus throughput for the given riser card used and the number of add-in cards installed. low profile riser 1 add-in card populated 2 add-in cards populated 1u ? 1 add-in card slot x8 or x4 na 2u ? 2 add-in card slots x4 x4 note: there are no population rules for installing a single low profile add-in card in the 2u lp riser card; a single add in card can be installed in either pci express* slot. while each slot can accommodate a x8 card, each slot will only support x4 bus speeds. the full height riser slot (j4f1) implements intel ? adaptive slot technology. this 280-pin connector is capable of supporting riser cards that meet either the pci-x* or pci express* technology specifications. the following tables show the maximum bus speed supported with different add-in card populations for each supported riser card. full height pci-x* (passive) riser 1 add-in card populated 2 add-in cards populated 3 add-in cards populated 1u ? 1 add-in card slot up to 133mhz na na 2u ? 3 add-in card slots up to 100mhz in top pci slot up to 100mhz using top and middle slots 66mhz note: for the 2u pci-x* (passive) riser card, add-in cards should be installed starting with the top slot first, followed by the middle, and th en the bottom. any add-in card popu lated in the bottom pci slot will cause the bus to operate at 66mhz. full height pci-x* (active) riser 1 add-in card populated 2 add-in cards populated 3 add-in cards populated 2u ? 3 add-in card slots up to 133mhz up to 133mhz up to 133mhz note: each pci slot on the 2u pci-x* (active) riser card operates on an independent pci bus. therefore, using an add-in card that operates below 133mhz w ill not affect the bus speed of the other pci slots.
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 35 full height pci express* riser 1 add-in card populated 2 add-in cards populated 3 add-in cards populated 1u ? 1 add-in card slot x4 or x8 na na 2u ? 3 add-in card slots si ngle pcie* x4 in either slot or x8 in middle slot or pci-x* ? up to 133mhz in bottom slot single pcie* ? x4 in either slot or x8 in middle slot and pci-x* ? up to 133mhz or dual pcie ? x4 dual pcie* ? x4 and pci-x* ? up to 133mhz 3.2.2 serial ata support the esb-2 has an integrated serial ata (sata) controller that supports independent dma operation on six ports and supports data transfer rates of up to 3.0 gb/s. the six sata ports on the server board are numbered sata-0 thru sata-5. the sata ports can be enabled/disabled and/or configured by accessing the bios setup utility during post. 3.2.2.1 intel ? embedded server raid technology ii support the onboard storage ca pability of this server boar d includes support for intel ? embedded server raid technology which provides three standard software raid levels: data stripping (raid level 0), data mirroring (raid level 1), and data stripping with mirroring (raid level 10). for higher performance, data stripping can be used to alleviate disk bottlenecks by taking advantage of the dual independent dma engines that each sata port offers. data mirroring is used for data security. should a disk fail, a mirrored copy of the failed disk is brought on-line. there is no loss of either pci resources (request/grant pair) or add-in card slots. with the addition of an optional intel raid activation key, intel ? embedded server raid technology is also capable of providing fault tolerant data stripping (software raid level 5), such that if a sata hard drive should fail, the lost data can be restored on a replacement drive from the other drives that make up the raid 5 pack. see figure 1. components & connector location diagram for the location of intel raid activation key connector location. note: availability of the intel raid activation key to support software raid 5 w ill be deferred until after product launch of this server board. intel ? embedded server raid technology functionality requires the following items: ? intel ? esb-2 io controller hub ? intel ? embedded server raid technology option rom ? intel ? application accelerator raid edition drivers, most recent revision ? at least two sata hard disk drives intel ? embedded server raid technology is not available in the following configurations: ? the sata controller in compatible mode ? intel ? embedded server raid technology has been disabled
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 36 3.2.2.2 intel ? embedded server raid technology option rom the intel ? embedded server raid technology for sata option rom provides a pre-os user interface for the intel ? embedded server raid technology implementation and pr ovides the ability for an intel ? embedded server raid technology volume to be used as a boot disk as well as to detect any faults in the intel ? embedded server raid technology volume(s) attached to the intel ? raid controller. 3.2.3 parallel ata (pata) support the integrated ide controller of the esb-2 ich6 provides one ide channel. it redefines signals on the ide cable to allow both host and target throttling of data and transfer rates of up to 100mb/s. for this server board, the ide channel was designed to prov ide slim-line optical drive support to the platform. the bios initializes and supports atapi devices such as cdrom, cd-rw and dvd. the ide channel is accessed through a single high density 44-pin connector ((j3g1) which provides both power and io signals. the ata channel ca n be configured and enabled or disabl ed by accessing the bios setup utility during post. note: the ide connector on this server board is not a standard 40 ide connector. instead, this connector has an additional 4 power pins over and above the standard 40 i/o pins. the design intent of this connector is to provide suppor t for a slim-line optical drive only. 3.2.4 usb 2.0 support the usb controller functionality integrated into esb-2 provides the server board with the interface for up to eight usb 2.0 ports. two external connectors are located on the back edge of the server board. one internal 2x5 header is provided, capable of supporting two optional usb 2.0 ports. three usb ports are routed through the bridge board connector providing optional usb support for a system control panel or other usb requirements. an additional usb port is dedicated to the intel ? remote management module (intel ? rmm) connector. 3.3 video support the server board provides an ati* es1000 pci graphics accelerator, along with 16mb of video ddr sdram and support circuitry for an embedded svga video sub-system. the ati es1000 chip contains an svga video controller, clock generator, 2d engine, and ramdac in a 359-pin bga. one 4mx16x4 bank ddr sdram chip provides 16mb of video memory. the svga sub-system supports a variety of modes, up to 1024 x 768 resolution in 8 / 16 / 32bpp modes under 2d. it also supports both crt and lcd moni tors up to a 100 hz vertical refresh rate. video is accessed using a standard 15-pin vga connector found on the back edge of the server board. video signals are also made available through the 120-pin bridgeboard connector which provides signals for an optional video connector to be present on the platform?s control panel. video is routed to both the rear video connector and a control panel video connector. video is present at both connectors simultaneously and cannot be disabled at either connector individually. hot plugging the video while the system is still runnin g is supported. on-board video can be disa bled using the bios setup utility or when an add-in video card is installed. system bios also provides the option for dual video operation when an add-in video card is configured in the system.
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 37 3.3.1.1 video modes the ati es1000 chip supports all standard ibm* vga modes. the following table shows the 2d modes supported for both crt and lcd. table 5. video modes 2d video mode support 2d mode refresh rate (hz) 8 bpp 16 bpp 32 bpp 640x480 60, 72, 75, 85, 90, 100, 120, 160, 200 supported supported supported 800x600 60, 70, 72, 75, 85, 90, 100, 120,160 supported supported supported 1024x768 60, 70, 72, 75,85,90,100 supported supported supported 1152x864 43,47,60,70,75,80,85 supported supported supported 1280x1024 60,70,74,75 supported supported supported 1600x1200 52 supported supported supported 3.3.1.2 video memory interface the memory controller sub-system of the es1000 arbitrates requests from the direct memory interface, the vga graphics controller, the drawing co-processor, the display controller, the video scalar, and the hardware cursor. requests are se rviced in a manner that ensure s display integrity and maximum cpu/co-processor drawing performance. the server board supports a 16mb (4meg x 16-bit x 4 banks) ddr sdram device for video memory. 3.3.1.3 dual video the bios supports single and dual video modes. the dual video mode is enabled by default. ? in single mode (dual monitor video = disabled), the on-board video controller is disabled when an add-in video card is detected. ? in dual mode (on-board video = enabled, dual monitor video = enabled), the on-board video controller is enabled a nd will be the primary video device. the external vide o card will be allocated resources and is considered the secondary video device. bios setup provides user options to configure the feature as follows. on-board video enabled disabled dual monitor video enabled disabled shaded if on-board video is set to "disabled"
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 38 3.4 network interface controller (nic) network interface support is provided from the built in dual gbe mac features of the esb-2 in conjunction with the intel ? 82563eb compact physical layer transceiver (phy). together, they provide the server board with support for dual lan ports designed for 10/100/1000 mbps operation. the 82563eb device is based upon proven phy technology integrated into the intel ? gigabit ethernet controllers. the physical layer circuitry provides a standard ieee 802.3 ethernet interface for 1000base- t, 100base-tx, and 10base-t applications (802.3, 802.3u, and 802.3ab). the 82563eb device is capable of transmitting and receiving data at rates of 1000 mbps, 100 mbps, or 10 mbps each network interface controller (nic) drives two leds located on each network interface connector. the link/activity led (to the right of the connector) indicates network connection when on, and transmit/receive activity when blinking. the speed led (to the left of the connector) indicates 1000- mbps operation when amber, 100-mbps operation when green, and 10-mbps when off. the table below provides an overview of the leds. table 6. nic2 status led led color led state nic state off 10 mbps green 100 mbps green/amber (left) amber 1000 mbps on active connection green (right) blinking transmit / receive activity 3.4.1 intel ? i/o acceleration technology intel ? i/o acceleration technology moves network data more efficiently through dual-core intel ? xeon ? processor 5000 sequence-based servers for improved application responsiveness across diverse operating systems and virtualized environments. intel ? i/oat improves network application responsiveness by unleashing the power of dual-core intel ? xeon ? processors 5000 sequence through more efficient network data movement and reduced system overhead. intel multi-port network adapters with intel ? i/oat provide high-performance i/o for server consolidation and virtualization via stateless network acceleration that seamlessly scales across multiple ports and virtual machines. intel ? i/oat provides safe and flexible network acceleration through tight integration into popular operating systems & virtual machine monitors, avoiding the support risks of 3rd-party network stacks and preserving existing network requirements such as teaming and failover. 3.4.2 mac address definition each intel? server board s5000pal / s5000xal has four mac addresses assigned to it at the intel factory. during the manufacturing process, each server board will have a white mac address sticker placed on the board. the sticker will display the mac address in both bar code and alpha numeric formats. the printed mac address is assigned to nic 1 on the server board. nic 2 is assigned the nic 1 mac address + 1. two additional mac addresses are assigned to the baseboard management controller (bmc) embedded in the esb-2. these mac addresses are used by the bmc?s embedded network stack to enable ipmi remote management over lan. bmc lan channel 1 is assigned the nic1 mac address + 2, and bmc lan channel 2 is assigned the nic1 mac address + 3.
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 39 3.5 super i/o legacy i/o support is provided by using a national semiconductor* pc87427 super i/o device. this chip contains all of the necessary circuitry to support the following functions: ? gpios ? two serial ports ? keyboard and mouse support ? wake up control ? system health support 3.5.1.1 serial ports the server board provides two serial ports: an external rj45 serial port, and an internal dh10 serial header. serial a is an optional port accessed through a 9-pin internal dh-10 header. a standard dh10 to db9 cable can be used to direct the serial a port to the rear of a chassis. the serial a interface follows the standard rs232 pin-out as defined in the following table. table 7. serial a header pin-out pin signal name serial port a header pin-out 1 dcd 2 dsr 3 rx 4 rts 5 tx 6 cts 7 dtr 8 ri 9 gnd the rear rj45 serial b port is a fully functional serial port that can support any standard serial device. using an rj45 connector for a seria l port allows direct support for serial port concentrators, which typically use rj45 connectors and are widely used in the high-density server market. for server applications that use a serial concentrator to access the system management features of the server board, a standard 8-pin cat-5 cable from the serial concentrator is plugged directly into the rear rj45 serial port. to allow support for either of two serial port configuration standards, a jumper block located directly behind the rear rj45 serial port must be configured appropriately according to the desired standard. for serial concentrators that require a dcd signal, the jumper block must be configured with the serial port jumper over pins 1 and 2. for serial concentrators that require a dsr signal (default), the jumper block must be configured with the serial port jumper over pins 3 and 4. pin 1 on the jumper is identified by ? * ?. note: by default, the rear rj45 serial port is configured to support a dsr signal. this configuration is compatible with the cisco* standard.
functional architecture intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 40 tp02303 j8a3 1-2: dcd to dtr 3-4: dsr to dtr (factory default) 2 4 3 figure 15. serial port configuration jumper location for server applications that require a db9 serial connector, an 8-pin rj45-to-db9 adapter must be used. the following table provides the pin-out required for the adapter to provide rs232 support. a standard dh10-to-db9 cable and 8-pin rj45 to db9 dcd and dsr adapters are available from intel in the serial port accessory kit, product code: axxrj45db92. table 8. rear serial b port adapter pin-out rj45 signal abbreviation db9 1 request to send rts 7 2 data terminal ready dtr 4 3 transmitted data td 3 4 signal ground sgnd 5 5 ring indicator ri 9 6 received data rd 2 7 dcd or dsr dcd/dsr 1 or 6 (see note) 8 clear to send cts 8 note: the rj45-to-db9 adapter should match the configuration of the serial device used. one of two pin- out configurations is used, depending on whether the serial device requires a dsr or dcd signal. the final adapter configuration should also match the desired pin-out of the rj45 connector, as it can also be configured to support either dsr or dcd. 3.5.1.2 floppy disk controller the server board does not support a floppy disk controller (fdc) interface. however, the system bios does recognize usb floppy devices. 3.5.1.3 keyboard and mouse support dual stacked ps/2 ports, located on the back edge of the server board, are provided for keyboard and mouse support. either port can support a mouse or keyboard. neither port supports hot plugging. pins what happens at system reset? 1-2 serial port is configured for dcd to dtr 3-4 serial port is configured for dsr to dtr (default)
intel ? server board s5000pal / s5000xal tps functional architecture revision 1.7 intel order number: D31979-010 41 3.5.1.4 wake-up control the super i/o contains functionality that allows various events to power-on and power-off the system. 3.5.1.5 system health support the super i/o provides an interface via gpios for bios and server management firmware to activate the diagnostic leds, the fru fault indicator leds for processors, dimms, fans and the system status led. refer to figure 2. light guided diagnostic led location diagram for the location of the leds on the baseboard. the super i/o also provides pmw fan control to the system fans, monitors tach and presence signals for the system fans and monitors baseboard and control panel temperature.
platform management intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 42 4. platform management the platform management sub-system on the server board is based on the integrated baseboard management controller (bmc) features of the esb-2. the on board platform management subsystem consists of communication buses, sensors, system bios, and server management firmware. the following diagram provides an overview of the server management bus (smbus) architecture used on this server board. see appendix b for onboard sensor data. for more detailed platform management information, see the intel ? s5000 server board family datasheet. figure 16. smbus block diagram
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 43 5. connector / header locations and pin-outs 5.1 board connector information the following section provides deta iled information regardi ng all connectors, headers and jumpers on the server board. table 9 lists all connector types available on the board and the corresponding reference designators printed on the silkscreen. table 9. board connector matrix connector quantity reference designators connector type pin count power supply 3 j3k4 j3k3 j1k1 cpu power main power p/s aux 8 24 5 cpu 2 j8g1, j5g1 cpu sockets 771 main memory 8 j7b1,j7b2,j8b1,j8b2,j8b3,j9b1,j9b2, j9b3 dimm sockets 240 full height riser 1 j4f1 card edge 280 low profile riser 1 j5b1 card edge 98 bridge board connector 1 j4g1 card edge 120 rmm 1 j1c5 mezzanine 120 rmm nic 1 j1b2 mezzanine 30 intel ? i/o expansion module 1 j3b1 mezzanine 50 sata raid key 1 j1e4 key holder 3 ide (i/o + power) 1 j3g1 shrouded header 44 front system fans #1 & #2 2 j3k1, j3k2 header 4 rear system fans #3 & #4 2 j7a2, j7a1 header 4 cpu fans 2 j5k1, j9k1 header 4 battery 1 bt1j1 battery holder 3 keyboard/mouse 1 j9a1 ps2, stacked 12 rear usb 2 j5a1, j6a2 external 4 serial port a 1 j1b1 header 9 serial port b 1 j9a2 external, rj45 10 video connector 1 j6a1 external, d-sub 15 lan connector 10/100/1000 2 ja8a1, ja8a2 external lan connector with built-in magnetic 14 ssi control panel 1 j3h2 header 24 internal usb 1 j1j1 header 10 intrusion detect 2 j1c4 header 2 serial ata 6 j1h1,j1g2,j1g1,j1f2,j1f1,j1e3 header 7 lcp / aux ipmb 1 j1c2 header 4 ipmb 1 j1c3 header 3
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 44 connector quantity reference designators connector type pin count system recovery setting jumpers 4 j1d1, j1d2, j1d3, j3h1 jumper 3 5.2 power connectors the main power supply connection is obtained using an ssi compliant 2x12 pin connector (j3k3). in addition, there are two additional power related connectors; one ssi compliant 2x4 pin power connector (j3k4) providing support for additional 12v, and one ssi compliant 1x5 pin connector (j1k1) providing i 2 c monitoring of the power supply. the following tables define the connector pin-outs. table 10. power connector pin-out (j3k3) pin signal color pin signal color 1 +3.3vdc orange 13 +3.3vdc orange 2 +3.3vdc orange 14 -12vdc blue 3 gnd black 15 gnd black 4 +5vdc red 16 ps_on# green 5 gnd black 17 gnd black 6 +5vdc red 18 gnd black 7 gnd black 19 gnd black 8 pwr_ok gray 20 rsvd_(-5v) white 9 5vsb purple 21 +5vdc red 10 +12vdc yellow 22 +5vdc red 11 +12vdc yellow 23 +5vdc red 12 +3.3vdc orange 24 gnd black table 11. 12v power connector pin-out (j3k4) pin signal color 1 gnd black 2 gnd black 3 gnd black 4 gnd black 5 +12vdc yellow/black 6 +12vdc yellow/black 7 +12vdc yellow/black 8 +12vdc yellow/black table 12. power supply signal connector pin-out (j1k1) pin signal color 1 smb_clk_esb_fp_pwr_r orange 2 smb_dat_esb_fp_pwr_r black 3 smb_alrt_3_esb_r red 4 3.3v sense- yellow 5 3.3v sense+ green
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 45 5.3 system mana gement headers 5.3.1 intel ? remote management module (rmm) connector a 120-pin intel ? rmm connector (j1c5) is included on the server board for sole support of the optional intel ? remote management module. there is no support for third party asmi cards on this server board. note: this connector is not compatible for use with intel ? server management module professional edition (product code axximmpro) or the intel ? server management module advanced edition (product code axximmadv). table 13. intel ? rmm connector pin-out (j1c5) pin signal name pin signal name 1 reserved - nc 2 gnd 3 esb_plt_rst_g1_n 4 reserved - nc 5 gnd 6 reserved - nc 7 reserved - nc 8 gnd 9 reserved - nc 10 gnd 11 gnd 12 reserved - nc 13 gnd 14 irq_serial_r 15 usb_esb_p7p 16 gnd 17 usb_esb_p7n 18 gnd 19 gnd 20 reserved - nc 21 p3v3 22 reserved - nc 23 lpc_lad<0> 24 gnd 25 lpc_lad<1> 26 lpc_frame_n 27 p3v3 28 lpc_lad<2> 29 lpc_lclk 30 lpc_lad<3> 31 p3v3 32 p3v3 33 smb_1_3v3sb_ms_dat 34 smb_ipmb_3v3sb_dat 35 smb_1_3v3sb_sl_dat 36 smb_ipmb_3v3sb_clk 37 smb_1_3v3sb_ms_clk 38 smb_0_3v3sb_ms_clk 39 smb_1_3v3sb_int 40 smb_0_3v3sb_int 41 p3v3_aux 42 smb_0_3v3sb_ms_dat 43 spb_imm_dsr_n 44 smb_0_3v3sb_sl_dat 45 spb_imm_rts_n 46 p3v3_aux 47 spb_imm_cts_n 48 fm_imm_present_n 49 spb_imm_dcd_n 50 spb_imm_dtr_n 51 spb_ri_n 52 spb_imm_sin 53 spb_imm_sout 54 p3v3_aux 55 p3v3_aux 56 v_lcddata7 57 v_lcdcntl3 56 v_lcddata6 59 p3v3_aux 60 v_lcddata5 61 reserved - nc 62 v_lcddata4 63 reserved - nc 64 v_lcddata3 65 gnd 66 v_lcdcntl1 67 v_lcdcntl0 68 gnd 69 reserved - nc 70 v_lcddata15 71 gnd 72 v_lcddata714
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 46 pin signal name pin signal name 73 v_lcddata23 74 v_lcddata13 75 v_lcddata22 76 v_lcddata12 77 v_lcddata21 78 v_lcddata11 79 v_lcddata20 80 gnd 81 v_lcddata19 82 v_lcdcntl2 83 gnd 84 v_dvo_ddc_sda 85 fm_man_lan_type1 86 v_dvo_ddc_scl 87 fm_man_lan_type1 88 rst_ps_pwrgd 89 reserved - nc 90 reserved - nc 91 reserved - nc 92 reserved - nc 93 mii_mdc_rmii_spare 94 reserved - nc 95 mii_col_rmiib_rxer 96 gnd 97 gnd 98 mii_crs_rmiib_crs 99 mii_txer_rmiib_txen 100 mii_txclk_rmiib_rxclk 101 mii_mdio_rmiib_present 102 gnd 103 gnd 104 mii_txd3_rmiib_txd1 105 mii_rxd3_rmiib_rxd1 106 mii_txd2_rmiib_txd0 107 mii_rxd2_rmiib_rxd0 108 gnd 109 gnd 110 mii_txd1_rmiia_txd1 111 mii_rxd1_rmiia_rxd1 112 mii_txd0_rmiia_txd0 113 mii_rxd0_rmiia_rxd0 114 gnd 115 gnd 116 mii_txen_rmiia_txen 117 mii_rxclk 118 mii_rxer_rmiia_txer 119 mii_rxdv_rmiia_crs 120 gnd 5.3.2 intel ? rmm nic connector the server board provides an internal 30-pin mezzanine style connector (j1b2) to accommodate a proprietary form factor rmm nic module. the following table details the pin-out of the rmm nic module connector. table 14. 30-pin intel ? rmm nic module connector pin-out (j1b2) pin signal name pin signal name 1 fm_man_lan_type2 2 mii_mdc_rmii_spare 3 fm_man_lan_type1 4 mii_col_rmiib_rxer 5 gnd 6 gnd 7 mii_txclk_rmiib_rxclk 8 mii_txer_rmiib_txen 9 mii_crs_rmiib_crs 10 mii_mdio_rmiib_present 11 gnd 12 gnd 13 mii_txd2_rmiib_txd0 14 mii_rxd3_rmiib_rxd1 15 mii_txd1_rmiia_txd1 16 mii_rxd3_rmiib_rxd0 17 gnd 18 gnd 19 mii_txd3_rmiib_txd1 20 mii_rxd1_rmiia_rxd1 21 mii_txd0_rmiia_txd0 22 mii_rxd0_rmiia_rxd0 23 gnd 24 gnd 25 mii_txen_rmiia_txen 26 mii_rxclk 27 p3v3_aux 28 p3v3_aux 29 mii_rxer_rmiia_rxer 30 mii_rxdv_rmiia_crs
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 47 5.3.3 lcp/aux ipmb header table 15. lpc/aux ipmb header pin-out (j1c2) pin signal name description 1 smb_ipmb_5vsb_dat bmc imb 5v standby data line 2 gnd ground 3 smb_ipmb_5vsb_clk bmc imb 5v standby clock line 4 p5v_stby +5v standby power 5.3.4 ipmb header table 16. ipmb header pin-out (j1c3) pin signal name description 1 smb_ipmb_5vsb_dat bmc imb 5v standby data line 2 gnd 3 smb_ipmb_5vsb_clk bmc imb 5v standby clock line 5.4 riser card slots the server board has two riser card slots. th e full height riser slot (j4f1) utilizes intel ? adaptive slot technology. it is capable of supporting riser cards that support either the pci-x* or pci express* full height / full length add-in cards. the low profile riser slot (j5b1) supports riser cards that support low profile pci express* add-in cards. the following tables show the pin-out for these riser slots. table 17. low-profile riser slot pin-out (j5b1) pin side b pci spec signal pin side a pci spec signal 1 p12v 1 2 p12v 2 p12v 3 p12v 3 p12v 4 gnd 4 gnd 5 smb_pci3v3sb_clk 5 pd_lp_tck 6 smb_pci3v3sb_dat 6 pu_lp_tdi 7 gnd 7 fp_chassis_intru 8 p3v3 8 pu_lp_tms 9 pd_lptrst_n 9 p3v3 10 p3v3_aux 10 p3v3 11 pe_wake_n 11 pe_rst_lp_n 12 p3v3 12 gnd 13 gnd 13 clk_100m_lp_pcie_slot1_p 14 pe4_mch_txp_c <3..0> 0 14 clk_100m_lp_pcie_slot1_n 15 pe4_mch_txn_c <3..0> 0 15 gnd 16 gnd 16 pe4_mch_rxp <3..0> 0 17 17 pe4_mch_rxn <3..0> 0 18 gnd 18 gnd 19 pe4_mch_txp_c <3..0> 1 19 p3v3
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 48 pin side b pci spec signal pin side a pci spec signal 20 pe4_mch_txn_c <3..0> 1 20 gnd 21 gnd 21 pe4_mch_rxp <3..0> 1 22 gnd 22 pe4_mch_rxn <3..0> 1 23 pe4_mch_txp_c <3..0> 2 23 gnd 24 pe4_mch_txn_c <3..0> 2 24 gnd 25 gnd 25 pe4_mch_rxp <3..0> 2 26 gnd 26 pe4_mch_rxn <3..0> 2 27 pe4_mch_txp_c <3..0> 3 27 gnd 28 pe4_mch_txn_c <3..0> 3 28 gnd 29 gnd 29 pe4_mch_rxp <3..0> 3 30 p3v3 30 pe4_mch_rxn <3..0> 3 31 31 gnd 32 gnd 32 clk_100m_lp_pcie_slot2_p 33 pe5_mch_txp_c <3..0> 0 33 clk_100m_lp_pcie_slot2_n 34 pe5_mch_txn_c <3..0> 0 34 gnd 35 gnd 35 pe5_mch_rxp <3..0> 0 36 gnd 36 pe5_mch_rxn <3..0> 0 37 pe5_mch_txp_c <3..0> 1 37 gnd 38 pe5_mch_txn_c <3..0> 1 38 gnd 39 gnd 39 pe5_mch_rxp <3..0> 1 40 gnd 40 pe5_mch_rxn <3..0> 1 41 pe5_mch_txp_c <3..0> 2 41 gnd 42 pe5_mch_txn_c <3..0> 2 42 gnd 43 gnd 43 pe5_mch_rxp <3..0> 2 44 gnd 44 pe5_mch_rxn <3..0> 2 45 pe5_mch_txp_c <3..0> 3 45 gnd 46 pe5_mch_txn_c <3..0> 3 46 gnd 47 gnd 47 pe5_mch_rxp <3..0> 3 48 fm_lp_riser_type1 48 pe5_mch_rxn <3..0> 3 49 fm_lp_riser_type0 49 gnd table 18. full-height riser slot pin-out (j4f1) pin-side b pci spec signal pin-side a pci spec signal 140 12v 140 12v 139 12v 139 12v 138 ground 138 gnd 137 -12v 137 3.3vaux 136 12v 136 wake# 135 gnd 135 12v 134 refclk2+ 134 3.3v 133 refclk2+ 133 perst_n 132 gnd 132 gnd 131 gnd 131 refclk1+ 130 hsop(0) 130 refclk1+ 129 hson(0) 129 gnd
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 49 pin-side b pci spec signal pin-side a pci spec signal 128 gnd 128 hsip(0) 127 gnd 127 hsin(0) 126 hsop(1) 126 gnd 125 hson(1) 125 gnd 124 gnd 124 hsip(1) 123 gnd 123 hsin(1) 122 hsop(2) 122 gnd 121 hson(2) 121 gnd 120 gnd 120 hsip(2) 119 gnd 119 hsin(2) 118 hsop(3) 118 gnd 117 hson(3) 117 gnd 116 gnd 116 hsip(3) 115 gnd 115 hsin(3) 114 hsop(4) 114 gnd 113 hson(4) 113 gnd 112 gnd 112 hsip(4) 111 gnd 111 hsin(4) 110 hsop(5) 110 gnd 109 hson(6) 109 gnd 108 gnd 108 hsip(5) 107 gnd 107 hsin(5) 106 hsop(6) 106 gnd 105 hson(6) 105 gnd 104 gnd 104 hsip(6) 103 gnd 103 hsin(6) 102 hsop(7) 102 gnd 101 hson(7) 101 gnd 100 gnd 100 hsip(7) 99 +5v 99 hsin(7) 98 intb# 98 gnd 97 intd# 97 zcr_prsnt_l 96 +5v 96 +5v 95 reserved 95 +5v 94 +5v 94 zcr_mskid_l 93 iop inta 93 +5v 92 iop intb 92 inta# 91 gnd 91 intc# 90 clk3 90 gnd 89 gnd 89 req3# 88 clk2 88 gnd 87 gnd 87 gnt3# 86 req2# 86 gnd 85 gnd 85 rst# 84 reserved 84 gnd 83 gnd 83 reserved key key
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 50 pin-side b pci spec signal pin-side a pci spec signal key key 82 reserved 82 +5v 81 gnd 81 reserved 80 clk1 80 gnd 79 ground 79 gnt2# 78 req1# 78 +3.3v 77 +3.3v 77 gnt1# 76 pme2# 76 ground 75 ad[31] 75 pme1# 74 ad[29] 74 pme3# 73 ground 73 ad[30] 72 ad[27] 72 +3.3v 71 ad[25] 71 ad[28] 70 +3.3v 70 ad[26] 69 c/be[3]# 69 ground 68 ad[23] 68 ad[24] 67 ground 67 rsvrd 66 ad[21] 66 +3.3v 65 ad[19] 65 ad[22] 64 +3.3v 64 ad[20] 63 ad[17] 63 ground 62 c/be[2]# 62 ad[18] 61 ground 61 ad[16] 60 irdy# 60 +3.3v 59 +3.3v 59 frame# 58 devsel# 58 ground 57 pci-xcap 57 trdy# 56 lock# 56 ground 55 perr# 55 stop# 54 +3.3v 54 +3.3v 53 serr# 53 smbd 52 +3.3v 52 smbclk 51 c/be[1]# 51 ground 50 ad[14] 50 par 49 ground 49 ad[15] 48 ad[12] 48 +3.3v 47 ad[10] 47 ad[13] 46 m66en 46 ad[11] 45 ground 45 ground 44 ground 44 ad[09] 43 ad[08] 43 c/be[0]# 42 ad[07] 42 +3.3v 41 +3.3v 41 ad[06] 40 ad[05] 40 ad[04] 39 ad[03] 39 ground 38 ground 38 ad[02] 37 ad[01] 37 ad[00]
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 51 pin-side b pci spec signal pin-side a pci spec signal 36 +3.3v 36 +3.3v 35 ack64# 35 req64# 34 +5v 34 +5v 33 +5v 33 +5v 32 reserved 32 +5v 31 ground 31 c/be[7]# 30 c/be[6]# 30 c/be[5]# 29 c/be[4]# 29 ground 28 ground 28 par64 27 ad[63] 27 ad[62] 26 ad[61] 26 3.3v 25 3.3v 25 ad[60] 24 ad[59] 24 ad[58] 23 ad[57] 23 ground 22 ground 22 ad[56] 21 ad[55] 21 ad[54] 20 ad[53] 20 3.3v 19 ground 19 ad[52] 18 ad[51] 18 ad[50] 17 ad[49] 17 ground 16 3.3v 16 ad[48] 15 ad[47] 15 ad[46] 14 ad[45] 14 ground 13 ground 13 ad[44] 12 ad[43] 12 ad[42] key key key key 11 ad[41] 11 3.3v 10 ground 10 ad[40] 9 ad[39] 9 ad[38] 8 ad[37] 8 ground 7 3.3v 7 ad[36] 6 ad[35] 6 ad[34] 5 ad[33] 5 ground 4 ground 4 ad[32] 3 type1 3 pxh_rst_n 2 type0 2 ground 1 size 1 pxh_pwrok
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 52 5.5 ssi control panel connector the server board provides a 24-pin ssi control panel connector (j3h2) for use with non-intel chassis. the following table provides the pin-out for this connector. table 19. front panel ssi standard 24-pin connector pin-out (j3h2) pin signal name pin signal name 1 p3v3_stby 2 p3v3_stby 3 key 4 p5v_stby 5 fp_pwr_led_l 6 fp_id_led_l 7 p3v3 8 fp_status_led1_r 9 hdd_led_act_r 10 fp_status_led2_r 11 fp_pwr_btn_l 12 lan_act_a_l 13 gnd 14 lan_linka_l 15 reset button 16 ps_i2c_3vsb_sda 17 gnd 18 ps_i2c_3vsb_scl 19 fp_id_btn_l 20 fp_chassis_intru 21 temp_sensor 22 lan_act_b_l 23 fp_nmi_btn_l 24 lan_linkb_l 5.6 bridge board connector for use in supported intel ? server chassis, the server board provides a 120-pin high-density bridge board connector (j4g1) to route control panel, mid-plane, and backplane signals from the server board to the specified system board. the following table provides the pin-outs for this connector. table 20. 120-pin bridgeboard connector pin-out (j4g1) pin signal name pin signal name a1 smb_host_3v3_clk b1 gnd a2 smb_host_3v3_dat b2 pe1_esb_txn_c<3> a3 fm_bridge_present_n b3 pe1_esb_txp_c<3> a4 gnd b4 gnd a5 pe1_esb_rxn_c<3> b5 pe_wake_n a6 pe1_esb_rxp_c<3> b6 gnd a7 gnd b7 pe1_esb_txn_c<2> a8 fm_fan_d_prsnt6 b8 pe1_esb_txp_c<2> a9 gnd b9 gnd a10 pe1_esb_rxn_c<2> b10 fm_fan_d_prsnt5 a11 pe1_esb_rxp_c<2> b11 gnd a12 gnd b12 pe1_esb_txn_c<1> a13 fm_fan_d_prsnt4 b13 pe1_esb_txp_c<1> a14 gnd b14 gnd a15 pe1_esb_rxn_c<1> b15 rst_mp_pwrgd a16 pe1_esb_rxp_c<1> b16 gnd a17 gnd b17 pe1_esb_txn_c<0> a18 fm_raid_present b18 pe1_esb_txp_c<0>
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 53 pin signal name pin signal name a19 gnd b19 gnd a20 pe1_esb_rxn_c<0> b20 fm_raid_mode a21 pe1_esb_rxp_c<0> b21 gnd a22 gnd b22 clk_100m_srlake_n a23 fm_fan_d_prsnt1 b23 clk_100m_srlake_p a24 fm_fan_d_prsnt3 b24 gnd a25 fm_fan_d_prsnt2 b25 sgpio_dataout1_r a26 gnd b26 sgpio_dataout0_r a27 usb_esb_p4p b27 sgpio_load_r a28 usb_esb_p4n b28 sgpio_clock_n a29 gnd b29 gnd a30 usb_esb_oc_n<4> b30 usb_esb_p2p a31 usb_esb_oc_n<3> b31 usb_esb_p2n a32 gnd b32 gnd a33 usb_esb_p3p b33 usb_esb_oc_n<2> a34 usb_esb_p3n b34 nic1_link_led_n a35 gnd b35 nic1_act_led_n a36 fp_nmi_btn_n b36 led_status_green_r1 key key a37 bmc_rst_btn_n b37 nic2_link_led_n a38 fp_pwr_btn_n b38 nic2_act_led_n a39 fp_id_btn b39 led_status_amber_r1 a40 gnd b40 gnd a41 smb_ipmb_ 5vsb_sda b41 smb_sn_3v3sb_dat_buf a42 smb_ipmb_ 5vsb_clk b42 smb_sn_3v3sb_clk_buf a43 gnd b43 gnd a44 led_ hdd_activity_n b44 v_io_hsync2_buf_fp a45 p3v3 b45 v_io_vsync2_buf_fp a46 fp_pwr_led_n_r b46 gnd a47 p3v3_stby b47 v_io_blue_conn_fp a48 fp_id_led_r1_n b48 v_io_green_conn_fp a49 fm_sio_temp_sensor b49 v_io_red_conn_fp a50 led_fan3_fault b50 gnd a51 led_fan2_fault b51 led_fan10_fault a52 led_fan1_fault b52 led_fan5_fault a53 fan_pwm_cpu1 b53 led_fan4_fault a54 gnd b54 fan_io_pwm a55 fan_pwm_cpu2 b55 gnd a56 pci_fan_tach9 b56 pci_fan_tach10 a57 fan_tach7 b57 fan_tach8 a58 fan_tach5 b58 fan_tach6 a59 fan_tach3_h7 b59 fan_tach4_h7 a60 fan_tach1_h7 b60 fan_tach2_h7
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 54 5.7 i/o connector pin-out definition 5.7.1 vga connector the following table details the pin-out definition of the vga connector (j6a1). table 21. vga connector pin-out (j6a1) pin signal name description 1 v_io_r_conn red (analog color signal r) 2 v_io_g_conn green (analog color signal g) 3 v_io_b_conn blue (analog color signal b) 4 tp_vid_conn_b4 no connection 5 gnd ground 6 gnd ground 7 gnd ground 8 gnd ground 9 tp_vid_conn_b9 no connection 10 gnd ground 11 tp_vid_conn_b11 no connection 12 v_io_ddcdat ddcdat 13 v_io_hsync_conn hsync (horizontal sync) 14 v_io_vsync_conn vsync (vertical sync) 15 v_io_ddcclk ddcclk 5.7.2 nic connectors the server board provides two rj45 nic connectors oriented side by side on the back edge of the board (ja8a1, ja8a2). the pin-out for each connector is identical and is defined in the following table. table 22. rj-45 10/100/1000 nic connector pin-out (ja8a1, ja8a2) pin signal name 1 gnd 2 p1v8_nic 3 nic_a_mdi3p 4 nic_a_mdi3n 5 nic_a_mdi2p 6 nic_a_mdi2n 7 nic_a_mdi1p 8 nic_a_mdi1n 9 nic_a_mdi0p 10 nic_a_mdi0n 11 (d1) nic_linka_1000_n (led 12 (d2) nic_linka_100_n (led) 13 (d3) nic_act_led_n 14 nic_link_led_n 15 gnd 16 gnd
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 55 5.7.3 ide connector the server board includes an ide connector to access the single ide channel from the esb-2 io controller hub. the design intent fo r this connector is to provide ide support for a single slim-line optical drive, such as cdrom or dvd. the connector is not a standard 40-pin ide connector, instead it has 44 pins providing support for both power and io signals. the pin-out for this connector is defined in the following table. table 23. 44-pin ide connector pin-out (j3g1) pin signal name pin signal name 1 esb_plt_rst_ide_n 2 gnd 3 ride_dd_7 4 ride_dd_8 5 ride_dd_6 6 ride_dd_9 7 ride_dd_5 8 ride_dd_10 9 ride_dd_4 10 ride_dd_11 11 ride_dd_3 12 ride_dd_12 13 ride_dd_2 14 ride_dd_13 15 ride_dd_1 16 ride_dd_14 17 ride_dd_0 18 ride_dd_15 19 gnd 20 key 21 ride_ddreq 22 gnd 23 ride_diow_n 24 gnd 25 ride_dior_n 26 gnd 27 ride_piordy 28 gnd 29 ride_ddack_n 30 gnd 31 irq_ide 32 tp_pide_32 33 ride_da1 34 ide_pri_cblsns 35 ride_da0 36 ride_da2 37 ride_dcs1_n 38 ride_dcs3_n 39 led_ide_n 40 gnd 41 p5v 42 p5v 43 gnd 44 gnd 5.7.4 intel ? i/o expansion module connector the server board provides an internal 50-pin mezzanine style connector (j3b1) to accommodate proprietary form factor intel ? i/o expansion modules, which expand th e io capabilities of the server board without sacrificing an add-in slot from the riser cards. there are three planned io modules for use on this server board: external 4 port sas, dual gb nic, and infiniband*. for more detail on the supported io modules, please refer to the intel ? server board s5000pal / s5000xal io module hardware specification . the following table details the pin-out of the intel ? i/o expansion module connector.
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 56 table 24. 50-pin intel ? i/o expansion module connector pin-out (j3b1) pin signal name pin signal name 1 p3v3_aux 2 p3v3_aux 3 pe_rst_g2_pm_n 4 gnd 5 gnd 6 pe2_esb_rxp_c<0> 7 gnd 8 pe2_esb_rxn_c<0> 9 pe2_esb_txp_c<0> 10 gnd 11 pe2_esb_txn_c<0> 12 gnd 13 gnd 14 pe2_esb_rxp_c<1> 15 gnd 16 pe2_esb_rxn_c<1> 17 pe2_esb_txp_c<2> 18 gnd 19 pe2_esb_txn_c<2> 20 gnd 21 gnd 22 pe2_esb_rxp_c<2> 22 gnd 24 pe2_esb_rxn_c<2> 25 pe2_esb_txp_c<1> 26 gnd 27 pe2_esb_txn_c<1> 28 gnd 29 gnd 30 pe2_esb_rxp_c<3> 31 gnd 32 pe2_esb_rxn_c<3> 33 pe2_esb_txp_c<0> 34 gnd 35 pe2_esb_txn_c<0> 36 gnd 37 gnd 38 clk_100m_lp_pcie_slot3_p 39 gnd 40 clk_100m_lp_pcie_slot3_n 41 pe_wake_n 42 gnd 43 p3v3 44 p3v3 45 p3v3 46 p3v3 47 p3v3 48 p3v3 49 p3v3 50 p3v3 5.7.5 sata connectors the server board provides six sata (serial ata) connectors: sata-0 (j1h1), sata-1 (j1g2), sata-2 (j1g1), sata-3 (j1f2), sata-4 (j1f1), and sata-5 (j1e3), for use with an internal sata backplane. the pin configuration for each connector is identical and is defined in the following table. table 25. sata connector pin-out (j1h1, j1g2, j1g1, j1f2, j1e3) pin signal name description 1 gnd gnd1 2 sata#_tx_p_c positive side of transmit differential pair 3 sata#_tx_n_c negative side of transmit differential pair 4 gnd gnd2 5 sata#_rx_n_c negative side of receive differential pair 6 sata#_rx_p_c positive side of receive differential pair 7 gnd gnd3
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 57 5.7.6 serial port connectors the server board provides one external rj45 serial ?b ? port (j9a2) and one internal 9-pin serial ?a? port header (j1b1). the following tables define the pin-outs for each. table 26. external rj-45 serial ?b? port pin-out (j9a2) pin signal name description 1 spb_rts rts (request to send) 2 spb_dtr dtr (data terminal ready) 3 spb_out_n txd (transmit data) 4 gnd ground 5 spb_ri ri (ring indicate) 6 spb_sin_n rxd (receive data) 7 spb_dsr _dcd data set ready / data carrier detect 1 8 spb_cts cts (clear to send) note: 1 a jumper block on the server board will determine whether dsr or dcd is routed to pin 7. the board will have the jumper block configured with dsr enabled at production. table 27. internal 9-pin serial ?a? header pin-out (j1b1) pin signal name description 1 spa_dcd dcd (carrier detect) 2 spa_dsr dsr (data set ready) 3 spa_sin_l rxd (receive data) 4 spa_rts rts (request to send) 5 spa_sout_n txd (transmit data) 6 spa_cts cts (clear to send) 7 spa_dtr dtr (data terminal ready) 8 spa_ri ri (ring indicate) 9 gnd ground 5.7.7 keyboard and mouse connector two stacked ps/2 ports (j9a1) are provided to support both a keyboard and a mouse. either ps/2 port can support a mouse or keyboard. the following table details the pin-out of the ps/2 connector. table 28. stacked ps/2 keyboard and mouse port pin-out (j9a1) pin signal name description 1 kb_data_f keyboard data 2 tp_ps2_2 test point ? keyboard 3 gnd ground 4 p5v_kb_f keyboard / mouse power 5 kb_clk_f keyboard clock 6 tp_ps2_6 test point ? keyboard / mouse 7 ms_dat_f mouse data 8 tp_ps2_8 test point ? keyboard / mouse 9 gnd ground
connector / header locations and pin-outs intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 58 pin signal name description 10 p5v_kb_f keyboard / mouse power 11 ms_clk_f mouse clock 12 tp_ps2_12 test point ? keyboard / mouse 13 gnd ground 14 gnd ground 15 gnd ground 16 gnd ground 17 gnd ground 5.7.8 usb 2.0 connectors the following table details the pin-out of the external usb connectors (j5a1, j6a2) found on the back edge of the server board. table 29. external usb connector pin-out (j5a1, j6a2) pin signal name description 1 usb_oc#_fb_1 usb_pwr 2 usb_p#n_fb_2 datal0 (differential data line paired with datah0) 3 usb_p#n_fb_2 datah0 (differential data line paired with datal0) 4 gnd ground one 2x5 header on the server board (j1j1) provides an option to support an additional two usb 2.0 ports. the pin-out of the connector is detailed in the following table. table 30. internal usb connector pin-out (j1j1) pin signal name description 1 p5v_usb2_vbus0 usb power (ports 0,1) 2 p5v_usb2_vbus1 usb power (ports 0,1) 3 usb_esb_p0n_conn usb port 0 negative signal 4 usb_esb_p1n_conn usb port 0 positive signal 5 usb_esb_p0p_conn usb port 1 negative signal 6 usb_esb_p1p_conn usb port 1 positive signal 7 ground 8 ground 9 -- no pin 10 tp_usb_esb_nc test point
intel ? server board s5000pal / s5000xal tps connector / header locations and pin-outs revision 1.7 intel order number: D31979-010 59 5.8 fan headers the server board incorporates three system fan circuits which support a total of six ssi compliant 4-pin fan connectors. two fan connectors are designated as processor cooling fans, cpu1 fan (j9k1) and cpu2 fan (j5k1). these connectors can support cpu fans that draw a maximum of 1.2 amps each. two system fan connectors can be found towards the front edge of the server board, system fan 1 (j3k1), system fan 2 (j3k2). these connectors are capable of supporting a maximum fan load of 3.5 amps each. two additional system fan connectors can be found near the back edge of the server board, system fan 3(j7a1) and system fan 4 (j7a2). these two connectors are capable of supporting a maximum fan load of 2.5 amps per connector. with the proper sensor data record (sdr) installed, server management software can monitor all system fans in use. the pin configuration for each fan connector is identical and is defined in the following table. table 31. ssi fan connector pin-out (j9k1,j5k1,j3k1,j3k2,j7a2,j7a1) pin signal name type description 1 ground gnd ground is the power supply ground 2 12v power power supply 12v 3 fan tach out fan_tach signal is connected to the bmc to monitor the fan speed 4 fan pwm in fan_pwm signal to control fan speed note : intel corporation server baseboards support peripheral components and contain a number of high- density vlsi and power delivery components that need adequate airflow to cool. intel?s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. it is the responsi bility of the system integrator that chooses not to use intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. intel corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits
jumper block settings intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 60 6. jumper block settings the server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or recover specific features of the server board. pin 1 on each jumper block is denoted by an ?*? or ? ?. 6.1 recovery jumper blocks table 32. recovery jumpers (j1d1, j1d2, j1d3) jumper name pins what happens at system reset? 1-2 bmc firmware force update mode ? disabled (default) j1d1: bmc force update 2-3 bmc firmware force update mode ? enabled 1-2 these pins should have a jumper in pl ace for normal system operation. (default) j1d2: password clear 2-3 if these pins are jumpered, administrator and user passwords will be cleared immediately. these pins should not be jumpered for normal operation. 1-2 these pins should have a jumper in pl ace for normal system operation. (default) j1d3: cmos clear 2-3 if these pins are jumpered, the cmos setting s will be cleared immediately. these pins should not be jumpered for normal operation tp02080 3 2 password reset j1d2 j1d3 3 2 clear cmos bmc force update mode 3 2 j1d1 disable enable figure 17. recovery jumper blocks (j1d1, j1d2, j1d3)
intel ? server board s5000pal / s5000xal tps jumper block settings revision 1.7 intel order number: D31979-010 61 6.1.1 cmos clear and password reset usage procedure the cmos clear (j1d3) and password reset (j1d2) recovery features are designed so that the desired operation can be achieved with minimal system down time. the usage procedure for these two features has changed from previous generation intel ? server boards. the following procedure outlines the new usage model. cmos clear procedure: 1. power down the server; do not remove ac power. 2. open the server and move the jumper from the default operating position (pins1-2) to the ?clear? position (pins 2-3). 3. wait 5 seconds. 4. move the jumper back to the default position (pins 1-2). 5. close the server system and power up the server. 6. cmos is now cleared and can be reset by going into the bios setup. password reset procedure: 1. power down the server; do not remove ac power. 2. open the server and move the jumper from the default operating position (pins1-2) to the ?reset? position (pins 2-3). 3. power up the server. 4. the password is now cleared. 5. power down the server; do not remove ac power. 6. move the jumper back to the default position (pins 1-2) and close the server system. 7. the password can be reset by going into the bios setup. note: removing ac power before perf orming the cmos clear operation will cause the system to automatically power up and immediately power down, after the procedure is followed and ac power is re- applied. should this occur, remove the ac power cord again, wait 30 seconds, and re-install the ac power cord. power up system and proceed to the bios setup utility to reset desired settings. 6.1.2 bmc force update procedure when performing a standard bmc firmware update procedure, the update utility places the bmc into an update mode, allowing the firmware to load safely onto the flash device. in the unlikely event that the bmc firmware update process fails due to the bmc not being in the proper update state, the server board provides a bmc force update jumper (j1d1) which will force the bmc into the proper update state. the following procedure should be following in the event the standard bmc firmware update process fails. ? power down the server and remove ac power. ? open the server and move the jumper from the default operating position (pins1-2) to the ?enabled? position (pins 2-3). ? close the server system and reconnect ac power and power up the server. ? perform the standard bmc firmware update procedure as documented in readme.txt file that is included in the given bmc firmware update package. ? after successful completion of the firmware update process, the firmware update utility may generate an error stating that th e bmc is still in update mode. ? power down and remove ac power. ? open the server and move the jumper from the ?enabled? position (pins 2-3) to the ?disabled? position (pins 1-2). ? close the server system and reconnect ac power and power up the server.
jumper block settings intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 62 note: normal bmc functionality is disabled with the force bmc update jumper set to the ?enabled? position. the server should never be run with the bmc force update jumper set in this position and should only be used when the standard firmware update process fails. this jumper should remain in the default ? disabled position when the server is running normally. 6.2 bios select jumper the jumper block at j3h1, located just to the left of the ssi control panel header, is used to select which bios image the system will boot to. pin 1 on the jumper is identified with a ? ?. this jumper should only be moved if you wish to force the bios to boot to the secondary bank which may hold a different version of bios. the rolling bios feature of the base board will automatically alternate the boot bios to the secondary bank in the event the bios image in the primary bank is corrupted and cannot boot for any reason. tp02305 j3h1 2 3 2 3 1-2: force bios to bank 0 2-3: system is configured for normal operation (factory default) figure 18. bios select jumper (j3h1) pins what happens at system reset? 1-2 force bios to bank 0 2-3 system is configured for normal operation (default) note: when performing a bios update procedure, the bios select jumper must be set to its default position (pins 2-3).
intel ? server board s5000pal / s5000xal tps jumper block settings revision 1.7 intel order number: D31979-010 63 6.3 external rj45 serial port jumper block the jumper block j8a3, located directly behind the external rj45 serial port, is used to configure either a dsr or a dcd signal to the connector. tp02303 j8a3 1-2: dcd to dtr 3-4: dsr to dtr (factory default) 2 4 3 figure 19. external rj45 serial port configuration jumper
light guided diagnostics intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 64 7. light guided diagnostics the server board has several on-board diagnostic leds to assist in troubleshooting board level issues. this section shows where each led is located and provides a high level usage description. for a more detailed description of what drives the diagnostic led operation, refer to the intel ? s5000 series chipsets server board family datasheet. 7.1 5-volt standby led several server management features of this server board require that a 5 volt stand-by voltage be supplied from the power supply. some of the features and components that require this voltage be present when the system is ?off? include the bmc within the esb-2, onboard nics, and optional intel ? rmm. the led located just below the system recovery jump er block labeled ?5v stby? is illuminated when ac power is applied to the platform and 5 volt standby voltage is supplied to the server board by the power supply. tp02307 figure 20. 5v standby status led location
intel ? server board s5000pal / s5000xal tps light guided diagnostics revision 1.7 intel order number: D31979-010 65 7.2 system id led a nd system status led the server board provides leds for both system id and system status. tp02309 id led status led figure 21. system id led and system status led locations. the blue ?system id? led can be illumina ted using either of two mechanisms. ? by pressing the system id button on the system control panel the id led will display a solid blue color, until the button is pressed again. ? by issuing the appropriate hex ipmi ?chassis identify? value, the id led will either blink blue for 15 seconds and turn off or will b link indefinitely until the appropria te hex ipmi chassis identify value is issued to turn it off.
light guided diagnostics intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 66 the bi-color system status led will operate as follows: color state criticality description off n/a not ready ac power off green / amber alternating blink not ready pre dc power on ? 15-20 seco nd bmc initialization when ac is applied to the server. control panel buttons are disabled until bmc initialization is complete. green solid on system ok system booted and ready. green blink degraded system degraded ? unable to use all of the installed memory (more than one dimm installed). ? correctable errors over a threshold of 10 and migrating to a spare dimm (memory sparing). this indicates that the user no longer has spared dimms indicating a redundancy lost condition. corresponding dimm led should light up. ? in mirrored configuration, when memory mirroring takes place and system loses memory redundancy. this is not covered by (2). ? redundancy loss such as power-supply or fan. this does not apply to non-redundant sub-systems. ? pci-e link errors ? cpu failure / disabled ? if there are two processors and one of them fails ? fan alarm ? fan failure. number of operational fans should be more than minimum number needed to cool the system ? non-critical threshold crossed ? temperature and voltage ? chassis intrusion events, including lost lan connection amber blink non-critical non-fatal alarm ? system is likely to fail ? critical voltage threshold crossed ? vrd hot asserted ? minimum number of fans to co ol the system not present or failed ? in non-sparing and non-mirrorin g mode if the threshold of ten correctable errors is crossed within the window amber solid on critical, non- recoverable fatal alarm ? system has failed or shutdown ? dimm failure when there is one dimm present, no good memory present ? run-time memory uncorrectable error in non-redundant mode ? ierr signal asserted ? processor 1 missing ? temperature (cpu thermtrip, memory temphi, critical threshold crossed) ? no power good ? power fault ? processor configuration error (for instance, processor stepping mismatch) 7.2.1 system status led ? bmc initialization when the ac power is first applied to the system and 5v-stby is present, the bmc controller on the server board requires 15-20 seconds to initialize. during this time, the system status led will blink, alternating between amber and green, and the power button functionality of the control panel is disabled preventing the server from powering up. once bmc initialization has completed, the status led will stop blinking and the power button functionality is restored and can be used to turn on the server.
intel ? server board s5000pal / s5000xal tps light guided diagnostics revision 1.7 intel order number: D31979-010 67 7.3 dimm fault leds the server board provides a memory fault led for each dimm slot. the dimm fault led is illuminated when the system bios disables the specified dimm after it reaches a specified number of given failures or if specific critical dimm failures are detected. see the intel ? s5000 series chipsets server board family datasheet for more details. tp02310 figure 22. dimm fault led locations 7.4 processor fault led the server board provides a processor fault led fo r each of the two proces sor sockets. these leds will illuminate when a cpu is disabled or a cp u configuration error is detected. tp02311 cpu 2 cpu 1 figure 23. processor fault led location
light guided diagnostics intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 68 7.5 post code diagnostic leds during the system boot process, bios executes a number of platform configuration processes, each of which is assigned a specific hex post code number. as each configuration routine is started, bios will display the given post code to the post code diagnostic leds found on the back edge of the server board. to assist in troubleshooting a system hang during the post process, the diagnostic leds can be used to identify the last post process to be executed. see appendix c for a complete description of how these leds are read, and for a list of all supported post codes. tp02312 figure 24. post code diagnostic led location
intel ? server board s5000pal / s5000xal tps power and environmental specifications revision 1.7 intel order number: D31979-010 69 8. power and environmental specifications 8.1 intel? server board s5 000pal / s5000xal design specifications operation of the server board at conditions beyond those shown in the following table may cause permanent damage to the system. exposure to absolute maximum rating conditions for extended periods may affect system reliability. table 33: server board design specifications operating temperature 0o c to 55o c 1 (32o f to 131o f) non-operating temperature -40o c to 70o c (-40o f to 158o f) dc voltage 5% of all nominal voltages shock (unpackaged) trapezoidal, 50 g, 170 inches/sec shock (packaged) < 20 lbs 20 to < 40 40 to < 80 80 to < 100 100 to < 120 120 36 inches 30 inches 24 inches 18 inches 12 inches 9 inches vibration (unpackaged) 5 hz to 500 hz 3.13 g rms random note: 1 chassis design must provide proper airflow to avoid exceeding the dual-core intel ? xeon ? processor 5000 sequence maximum case temperature. disclaimer note : intel corporation server boards support add-in peripherals and contain a number of high-density vlsi and power delivery components that need adequate airflow to cool. intel ensures through its own chassis development and testing that when intel server building blocks are used together, the fully integrated system will me et the intended thermal requirement s of these components. it is the responsibility of the system integr ator who chooses not to use intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. intel corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
power and environmental specifications intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 70 8.2 server board power requirements this section provides power supply design guidelines for a system using the intel? server board s5000pal / s5000xal, including voltage and current specifications, and power supply on/off sequencing characteristics. the following diagram shows the power distribution implemented on this server board. figure 25. power distribution block diagram 8.2.1 processor power support the server board supports the thermal design point (tdp) guideline for dual-core intel ? xeon ? processors 5000 sequence. the flexible motherboard guidelines (fmb) has also been followed to help determine the suggested thermal and current design values for anticipating future processor needs. the following table provides maximum values for icc, tdp power and t case for the dual-core intel ? xeon ? processor 5000 sequence family. table 34. dual-core intel ? xeon ? processor 5000 sequence tdp guidelines per processor tdp power max tcase icc max 130 w 70o c 150 a note: these values are for reference only. the dual-core intel ? xeon ? processor 5000 sequence datasheet contains the actual specifications for the processor. if the values found in the dual-core intel ? xeon ? processor 5000 sequence datasheet are different than those published here, the dual-core intel ? xeon ? processor 5000 sequence datasheet values will supersede these, and should be used.
intel ? server board s5000pal / s5000xal tps power and environmental specifications revision 1.7 intel order number: D31979-010 71 8.2.2 power supply output requirements this section is for reference purposes only. its intent is to provide guidance to system designers for determining a proper power supply for use with this server board. the contents of this section specify the power supply requirements intel used to develop a power supply for its 1u server platform. the combined power of all outputs shall not exceed the rated output power of the power supply. the power supply must meet both static and dynamic voltage regulation requirements for the minimum loading conditions. table 35. 600w load ratings voltage minimum continuous maximum continuous peak +3.3 v 1.5 a 10 a +5 v 1.0 a 20 a +12 v1 0.5 a 16 a 18 a +12 v2 0.5 a 16 a 18 a +12 v3 0.5 a 16 a +12 v4 0.5 a 16 a -12 v 0 a 0.5 a +5 vsb 0.1 a 3.0 a 3.5 a 1. maximum continuous total dc output power should not exceed 600w. 2. peak load on the combined 12 v output shall not exceed 49a. 3. maximum continuous load on the combined 12 v output shall not exceed 44a. 4. peak total dc output power should not exceed 650w. 5. peak power and current loading shall be supported for a minimum of 12 seconds. 6. combined 3.3v and 5v power shall not exceed 100w. 8.2.3 turn on no load operation at power on the system shall present a no load condition to the power supply. in this no load state the voltage regulation limits for the 3.3v and 5v are relaxed to +/-10% and the +12v rails relaxed to +10/-8%. when operating loads are applied the voltages must regulated to there normal limits. table 36: no load operating range voltage minimum continuous maximum continuous peak +3.3 v 0 a 7 a +5 v 0 a 5 a +12 v1 0 a 5 a 7 a +12 v2 0 a 5 a 7 a +12 v3 0 a 6 a +12 v4 0 a 5 a -12 v 0 a 0.5 a +5 vsb 0.1 a 3.0 a 3.5 a
power and environmental specifications intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 72 8.2.4 grounding the grounds of the pins of the power supply output connector provide the power return path. the output connector ground pins shall be connected to safety ground (power supply enclosure). this grounding should be well designed to ensure passing the maximum allowed common mode noise levels. the power supply shall be provided with a reliable prot ective earth ground. all secondary circuits shall be connected to protective earth ground. resistance of the ground returns to chassis shall not exceed 1.0 m . this path may be used to carry dc current. 8.2.5 standby outputs the 5vsb output shall be present when an ac input greater than the power supply turn on voltage is applied. 8.2.6 remote sense the power supply has remote sense return (returns) to regulate out ground drops for all output voltages: +3.3v, +5v, +12v1, +12v2, +12v3, -12v, and 5vsb. the power supply uses remote sense (3.3vs) to regulate out drops in the system for the +3.3v output. the +5v, +12v1, +12v2, +12v3, ?12v and 5vsb outputs only use remote sense referenced to the returns signal. the remote sense input impedance to the power supply must be greater than 200 on 3.3vs and 5vs; this is the value of the resistor connecting the remote sense to the output voltage internal to the power supply. remote sense must be able to regulate out a minimum of a 200 mv drop on the +3.3v output. the remote sense return (returns) must be able to regulate out a minimum of a 200 mv drop in the power ground return. the current in any remote sense line shall be less than 5 ma to prevent voltage sensing errors. the power supply must operate within specification over the full range of voltage drops from the power supply?s output connector to the remote sense points. 8.2.7 voltage regulation the power supply output voltages must stay within the following voltage limits when operating at steady state and dynamic loading conditions. these limits include the peak-peak ripple/noise. table 37. voltage regulation limits parameter tolerance min nom max units + 3.3v - 5% / +5% +3.14 +3.30 +3.46 v rms + 5v - 5% / +5% +4.75 +5.00 +5.25 v rms + 12v1,2,3,4 - 5% / +5% +11.40 +12.00 +12.60 v rms - 12v - 5% / +9% -10.80 -12.00 -13.20 v rms + 5vsb - 5% / +5% +4.75 +5.00 +5.25 v rms
intel ? server board s5000pal / s5000xal tps power and environmental specifications revision 1.7 intel order number: D31979-010 73 8.2.8 dynamic loading the output voltages shall remain wi thin limits for the step loading and capacitive loading specified in the table below. the load transient repetition rate shall be tested between 50 hz and 5 khz at duty cycles ranging from 10%-90%. the load transient repetition rate is only a test specification. the step load may occur anywhere within the min load to the max load conditions. table 38. transient load requirements output step load size (see note 2) load slew rate test capacitive load +3.3v 5.0a 0.25 a/ sec 250 f +5v 6.0a 0.25 a/ sec 400 f 12v1+12v2+12v3+12 v4 28.0a 0.25 a/ sec 2200 f 1,2 +5vsb 0.5a 0.25 a/ sec 20 f notes: 1) step loads on each 12v output may happen simultaneously. 2) the +12v should be tested with 2200 f evenly split between the four +12v rails. 8.2.9 capacitive loading the power supply shall be stable and meet all requirements with the following capacitive loading ranges. table 39. capacitive loading conditions output min max units +3.3v 250 6,800 f +5v 400 4,700 f +12v1,2,3,4 500 each 11,000 f -12v 1 350 f +5vsb 20 350 f 8.2.10 closed-loop stability the power supply shall be unconditio nally stable under all line/load/tra nsient load conditions including capacitive load ranges. a minimum of: 45 degrees phase margin and -10db-gain margin is required. closed-loop stability must be ensured at the maximum and minimum loads as applicable. 8.2.11 common mode noise the common mode noise on any output shall not exceed 350 mv pk-pk over the frequency band of 10hz to 30mhz. 1. the measurement shall be made across a 100 ? resistor between each of the dc outputs, including ground, at the dc power connector and chassis ground (power subsystem enclosure). 2. the test set-up shall use an fet probe such as tektronix* model p6046 or equivalent.
power and environmental specifications intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 74 8.2.12 ripple / noise the maximum allowed ripple/noise output of the power supply is defined in the following table. this is measured over a bandwidth of 0hz to 20mhz at the power supply output connectors. a 10 f tantalum capacitor in parallel with a 0.1 f ceramic capacitor are placed at the point of measurement. table 40. ripple and noise +3.3v +5v +12v1/2/3/4 -12v +5vsb 50mvp-p 50mvp-p 120mvp-p 120mvp-p 50mvp-p 8.2.13 soft starting the power supply shall contain a control circuit which provides a monotonic soft start for its outputs without overstress of the ac line or any power supply components at any specified ac line or load conditions. there is no requirement for rise time on the 5 v standby, but the turn on/off shall be monotonic. 8.2.14 timing requirements these are the timing requirements for the power supply operation. the output voltages must rise from 10% to within regulation limits (t vout_rise ) within 5 to 70 ms, except for 5vsb; it is allowed to rise from 1.0 to 25 ms. all outputs must rise monotonically . each output voltage shall reach regulation within 50 ms (t vout_on ) of each other during turn on of the power supply. each output voltage shall fall out of regulation within 400 msec (t vout_off ) of each other during turn off. the following diagrams show the timing requirements for the power supply being turned on and off via the ac input with pson held low, and the pson signal with the ac input applied.
intel ? server board s5000pal / s5000xal tps power and environmental specifications revision 1.7 intel order number: D31979-010 75 table 41. output voltage timing item description min max units t vout_rise output voltage rise time from each main output. 5.0 * 70 1 msec t vout_on all main outputs must be within regulation of each other within this time. 50 msec t vout_off all main outputs must leave regulation within this time. 400 msec 1 the 5vsb output voltage rise time shall be from 1.0ms to 25.0ms tp02313 v out v1 v2 v3 v4 t vout_on t vout_rise 10% v out t vout_off figure 26. output voltage timing
power and environmental specifications intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 76 table 42. turn on/off timing item description min max units t sb_on_delay delay from ac being applied to 5vsb being within regulation. 1500 msec t ac_on_delay delay from ac being applied to all output voltages being within regulation. 2500 msec t vout_holdup time all output voltages stay within regulation after loss of ac. measured at 60% of maximum load. 21 msec t pwok_holdup delay from loss of ac to de-a ssertion of pwok. measured at 60% of maximum load. 20 msec t pson_on_delay delay from pson # active to output voltages within regulation limits. 5 400 msec t pson_pwok delay from pson # de-active to pwok being de-asserted. 50 msec t pwok_on delay from output voltages within regulation limits to pwok asserted at turn on. 100 500 msec t pwok_off delay from pwok de-asserted to output voltages (3.3v, 5v, 12v, -12v) dropping out of regulation limits. 1 msec t pwok_low duration of pwok being in the de-asserted state during an off/on cycle using ac or the pson signal. 100 msec t sb_vout delay from 5vsb being in regulation to o/ps being in regulation at ac turn on. 50 1000 msec t 5vsb_holdup time the 5vsb output voltage stays within regulation after loss of ac. 70 msec v out ac input pwok 5 vsb pson tp02314 t vout_holdup t ac_on_delay t sb_on_delay t pwok_on ac turn on/off cycle pson turn on/off cycle t sb_vout t 5vsb_holdup t pwok_holdup t pwok_off t pwok_low t pson_on_delay t sb_on_delay t pwok_on t pwok_off t pson_pwo k figure 27. turn on/off timing (power supply signals)
intel ? server board s5000pal / s5000xal tps power and environmental specifications revision 1.7 intel order number: D31979-010 77 8.2.15 residual voltage immunity in standby mode the power supply shall be immune to any residual voltage placed on its outputs (typically a leakage voltage through the system from standby output) up to 500 mv. there shall be no additional heat generated, nor stress of any internal components with this voltage applied to any individual output, and all outputs simultaneously. it also should not trip the power supply protection circuits during turn on. residual voltage at the power supply outputs for a no load condition shall not exceed 100 mv when ac voltage is applied and the pson# signal is de-asserted.
regulatory and certification information intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 78 9. regulatory and certification information 9.1 product regulatory compliance intended application ? this product was evaluated as information technology equipment (ite), which may be installed in offices, schools, computer rooms, and similar commercial type locations. the suitability of this product for othe r product categories and environments (such as: medical, industrial, telecommunications, nebs, residential, alarm systems, test equipment, etc.), other than an ite application, may require further evaluation. this is an fcc class a device. integration of it into a class b chassis does not result in a class b device. the following table references server board compliance and markings that may appear on the product. markings below are typical markings how ever, may vary or be different based on how certification is obtained. note: certifications emissions requirements are to class a 9.1.1 product safety & electromagnetic (emc) compliance compliance regional description compliance reference compliance reference marking example australia / new zealand as/nzs 3548 (emissions) n232 csa 60950 ? ul 60950 (safety) canada / usa industry canada ices-003 (emissions) canada ices-003 class a canada nmb-003 classe a cenelec europe low voltage directive 93/68/eec ; emc directive 89/336/eec en55022 (emissions) en55024 (immunity) ce declaration of conformity international cb cert ification ? iec60950 cispr 22 / cispr 24 none required korea rrl certification mic notice no. 1997-41 (emc) & 1997-42 (emi) ???? : cpu-model name (a) d33025 taiwan bsmi cns13438
intel ? server board s5000pal / s5000xal tps regulatory and certification information revision 1.7 intel order number: D31979-010 79 9.2 electromagnetic co mpatibility notices 9.2.1 fcc verification statement (usa) this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. intel corporation 5200 n.e. elam young parkway hillsboro, or 97124-6497 phone: 1-800-628-8686 this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. these limits are designed to provide reasonable protection against harmful interference in a residential installation. this equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. however, there is no guarantee that interfer ence will not occur in a particular installation. if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ? reorient or relocate the receiving antenna. ? increase the separation between the equipment and the receiver. ? connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ? consult the dealer or an experienced radio/tv technician for help. any changes or modifications not expressly approved by the grantee of this device could void the user?s authority to operate the equipment. the customer is responsible for ensuring compliance of the modified product. all cables used to connect to peripherals must be shielded and grounded. operation with cables, connected to peripherals that are not shielded and grounded may result in interference to radio and tv reception. 9.2.2 ices-003 (canada) cet appareil numrique respecte les limites bruits radiolectriques applicables aux appareils numriques de classe b prescrites dans la norme sur le matriel brouilleur: ?appareils numriques?, nmb-003 dicte par le ministre canadian des communications. english translation of the notice above: this digital apparatus does not exceed the class b limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled ?digital apparatus,? ices-003 of the canadian department of communications. 9.2.3 europe (ce declaration of conformity) this product has been tested in accordance too, and complies with the low voltage directive (73/23/eec) and emc directive (89/336/eec). the product has been marked with the ce mark to illustrate its compliance.
regulatory and certification information intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 80 9.2.4 bsmi (taiwan) the bsmi certification marking and emc warning is located on the outside rear area of the product. 9.2.5 rrl (korea) following is the rrl certific ation information for korea. english translation of the notice above: 1. type of equipment (model name): on license and product 2. certification no.: on rrl certificate. ob tain certificate from lo cal intel representative 3. name of certification re cipient: intel corporation 4. date of manufacturer: refer to date code on product 5. manufacturer/nation: intel corporation/re fer to country of origin marked on product
intel ? server board s5000pal / s5000xal tps regulatory and certification information revision 1.7 intel order number: D31979-010 81 9.3 product ecology compliance intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. the following is intel?s product ecology compliance criteria. compliance regional description compliance reference compliance reference marking example california california code of regulations, title 22, division 4.5; chapter 33: best management practices for perchlorate materials. special handling may apply. see www.dtsc.ca.gov/hazar douswaste/perchlorate this notice is required by california code of regulations, title 22, division 4.5; chapter 33: best management practices for perchlorate materials. this product / part include a battery which contains perchlorate material. china roh s administrative measures on the control of pollution caused by electronic information products? (eip) #39. referred to as china rohs. mark requires to be applied to retail products only. mark used is the environmental friendly use period (efup). number represents years. china china recycling (gb18455-2001) mark requires to be applied to be retail product only. marking applied to bulk packaging and single packages. not applied to internal packaging such as plastics, foams, etc. intel internal specification all materials, parts and subassemblies must not contain restricted materials as defined in intel?s environmental product content specification of suppliers and outsourced manufacturers ? http://supplier.intel.com/ehs/environmental.htm none required europe european directive 2002/95/ec - restriction of hazardous substances (rohs) threshold limits and banned substances are noted below. quantity limit of 0.1% by mass (1000 ppm) for: lead, mercury, hexavalent chromium, polybrominated biphenyls diphenyl ethers (pbb/pbde) quantity limit of 0.01% by mass (100 ppm) for: cadmium none required germany german green dot applied to retail packaging only for boxed boards
regulatory and certification information intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 82 compliance regional description compliance reference compliance reference marking example intel internal specification all materials, parts and subassemblies must not contain restricted materials as defined in intel?s environmental product content specification of suppliers and outsourced manufacturers ? http://supplier.intel.com/ehs/environmental.htm none required iso11469 - plastic parts weighing >25gm are intended to be marked with per iso11469. >pc/abs< international recycling markings ? fiberboard (fb) and cardboard (cb) are marked with international recycling marks. applied to outer bulk packaging and single package. japan japan recycling applied to retail packaging only for boxed boards 9.4 other markings compliance description compliance reference compliance reference marking example country of origin logistic requirements applied to products to indicate where product was made. made in xxxx
intel ? server board s5000pal / s5000xal tps appendix a: integration and usage tips revision 1.7 intel order number: D31979-010 83 appendix a: integration and usage tips ? when adding or removing components or peripherals from the server board, ac power must be removed. with ac power plugged into the server board, 5-volt standby is still present even though the server board is powered off. ? when two processors are installed, both must be of identical revision, core voltage, and bus/core speed. mixed processor steppings is supported. however, the stepping of one processor can not greater then one stepping back of the other. ? processors must be installed in order. cpu 1 is located near the edge of the server board and must be populated to operate the board. ? on the back edge of the server board are four diagnostic leds which display a sequence of red, green, or amber post codes during the boot process. if the server board hangs during post, the leds will display the last post event run before the hang. ? only fully buffered dimms (fbd) are supported on this server board. for a list of supported memory for this server board, see the intel? server board s5000pal / s5000xal tested memory list . ? for a list of intel supported operating systems, add-in cards, and peripherals for this server board, see the intel? server board s5000pal / s5000xal tested hardware and os list. ? only dual-core intel ? xeon ? processors 5000 sequence, with system bus speeds of 667/1066/1333 mhz are supported on this server board. previous generation intel ? xeon ? processors are not supported. ? for best performance, the number of dimms installed should be balanced across both memory branches. for example: a four dimm config uration will perform better than a two dimm configuration and should be installed in dimm slots a1, b1, c1, and d1. an eight dimm configuration will perform better then a six dimm configuration. ? there are no population rules for installing a single low profile add -in card in the 2u lp riser card; a single add in card can be installed in either pci express* slot. while each slot can accommodate a x8 card, each slot will only support x4 bus speeds. ? for the 2u pci-x* (passive) riser card, add-in cards should be installed starting with the top slot first, followed by the middle, and then the bottom. any add-in card populated in the bottom pci slot will cause the bus to operate at 66mhz. ? each pci slot on the 2u pci-x* (active) riser card operates on an independent pci bus. therefore, using an add-in card that operates below 13 3mhz will not affect the bus speed of the other pci slots. ? the ide connector on this server board is not a standard 40-pin ide connector. instead, this connector has an additional 4 power pins over and above the standard 40 i/o pins. the design intent of this connector is to provide support for a slim-line optical drive only. ? removing ac power before performing the cm os clear operation will cause the system to automatically power up and immediately power down after the procedure is followed and ac power is re-applied. should this occur, remove the ac power cord again, wait 30 seconds, and re-install the ac power cord. po wer up system and proceed to the bios setup utility to reset desired settings. ? normal bmc functionality is disabled with th e force bmc update jumper set to the ?enabled? position (pins 2-3). the server should never be run with the bmc force update jumper set in this position and should only be used when the standard firmware update process fails. this jumper should remain in th e default (disabled) position (pins 1-2) when the server is running normally. ? when performing a bios update procedure, the bios select jumper must be set to its default position (pins 2-3). ? when ac power is applied to the server, a 25-30 second delay is necessary to initialize the bmc. during this initialization period, the power button functionality is disabled.
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 84 appendix b: bmc sensor tables this appendix lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. see the intelligent platform management interface specification, version 1.5 , for sensor and event/reading-type table information. ? sensor type the sensor type references the values enumerated in the sensor type codes table in the ipmi specification. it provides the context in which to interpret the sensor, e.g., the physical entity or characteristic that is represented by this sensor. ? event / reading type the event/reading type references values from the event/reading type code ranges and generic event/reading type codes tables in the ipmi specification . note that digital sensors are a specific type of discrete sensors, which have only two states. ? event offset/triggers event thresholds are ?supported event generating thresholds? for threshold types of sensors. o [u,l][nr,c,nc]: upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical o uc, lc: upper critical, lower critical event triggers are ?supported event generating offsets? for discrete type sensors. the offsets can be found in the generic event/reading type codes or sensor type codes tables in the ipmi specification, depending on whether the sensor event/reading type is generic or a sensor specific response. ? assertion / de-assertion enables assertion and de-assertion indicators reveal the type of events the sensor can generate: o as: assertions o de: de-assertion ? readable value / offsets o readable value indicates the type of value returned for threshold and other non-discrete type sensors. o readable offsets indicate the offsets for discrete sensors that are readable via the get sensor reading command. unless otherwise indicated, all event triggers are readable, i.e., readable offsets consists of the reading type offsets that do not generate events. ? event data this is the data that is included in an event message generated by the associated sensor. for threshold-based sensors, the following abbreviations are used: o r: reading value o t: threshold value
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 85 ? rearm sensors - the rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. rearming the sensors can be done manually or automatically. this column indicates the type supported by the sensor. the following abbreviations are used in the comment column to describe a sensor: a: auto-rearm m: manual rearm ? default hysteresis - hysteresis setting applies to all thresholds of the sensor. this column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis). ? criticality - criticality is a classification of the severity and nature of the condition. it also controls the behavior of the control panel status led. ? standby - some sensors operate on standby power. these sensors may be accessed and / or generate events when the main (system) power is off, but ac power is present.
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 86 table 43. bmc sensors sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby power down power cycle a/c lost ok soft power control failure power unit failure critical power unit status 01h all power unit 09h sensor specific 6fh predictive failure non-critical as ? trig offset a x redundancy regained non-red: suff res from redund ok redundancy lost redundancy degraded degraded non-red: suff from insuff ok non-red: insufficient critical power unit redun- dancy 02h chassis- specific power unit 09h generic 0bh redun degrade from full redun degrade from non- redundant ok as ? trig offset a x
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 87 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby watchdog 03h all watchdog 2 23h sensor specific 6fh timer expired, status only hard reset power down power cycle timer interrupt ok as ? trig offset a x platform security violation 04h all platform security violation attempt 06h sensor specific 6fh secure mode violation attempt out-of-band access password violation ok as ? trig offset a x physical security 05h chassis intrusion is chassis- specific physical security 05h sensor specific 6fh chassis intrusion lan leash lost 1 ok as and de ? trig offset a x fp diag interrupt (nmi) 07h all critical interrupt 13h sensor specific 6fh front panel nmi / diagnostic interrupt bus uncorrectable error ok as ? trig offset a ? system event log 09h all event logging disabled 10h sensor specific 6fh log area reset / cleared ok as ? trig offset a x session audit 0ah all session audit 2ah sensor specific 6fh 00h ? session activation 01h ? session deactivation ok as ? as defined by ipmi a x
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 88 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby system event ('system event') 0bh all system event 12h sensor specific 6fh 00 ? system reconfigured 04 ? pef action ok as ? trig offset a x bb +1.2v vtt 10h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb+1.9v nic core 11h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a x bb +1.5v aux 12h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +1.5v 13h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +1.8v 14h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +3.3v 15h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +3.3v stb 16h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a x bb +1.5v esb 17h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a x bb +5v 18h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +1.2v nic 19h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb +12v aux 1ah all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb 0.9v 1bh all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bb vbat 1eh all voltage 02h digital discrete 05h 01h ? limit exceeded critical as and de ? r, t a x
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 89 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby bb temp 30h all temperature 01h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a x front panel temp 32h all temperature 01h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a x fan 1a 50h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 2a 51h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 3a 52h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 4a 53h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 5a 54h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? tach fan (not used on this server) 55h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 1b 56h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 2b 57h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 3b 58h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 4b 59h chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 5b 5ah chassis- specific fan 04h threshold 01h [l] [c,nc] threshold defined as and de analog r, t m ? fan 1 present 60h chassis- specific fan 04h generic 08h device present ok as and de ? t a ?
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 90 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby fan 2 present 61h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 3 present 62h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 4 present 63h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 5 present 64h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 6 present 65h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 7 present 66h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 8 present 67h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 9 present 68h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? fan 10 present 69h chassis- specific fan 04h generic 08h device present ok as and de ? t a ? redundancy regained ok redundancy lost redundancy degraded degraded non-red: suff res from redund non-red: suff from insuff ok fan redun- dancy 6fh chassis- specific fan 04h generic 0bh non-red: insufficient critical as ? trig offset a x
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 91 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby redun degrade from full redun degrade from non- redundant ok presence ok failure critical predictive fail non-critical a/c lost critical power supply status 1 70h chassis- specific power supply 08h sensor specific 6fh configuration error non-critical as and de ? trig offset a x presence ok failure critical predictive fail non-critical a/c lost critical power supply status 2 71h chassis- specific power supply 08h sensor specific 6fh configuration error non-critical as and de ? trig offset a x power nozzle power supply 1 78h chassis- specific current 03h threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ? power nozzle power supply 2 79h chassis- specific current 03h threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ? power gauge v1 rail (+12v) power supply 1 7ah chassis- specific current 03h threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ?
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 92 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby power gauge v1 rail (+12v) power supply 2 7bh chassis- specific current 03h threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ? power gauge (aggre- gate power) power supply 1 7ch chassis- specific other units 0bh threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ? power gauge (aggregate power) power supply 2 7dh chassis- specific other units 0bh threshold 01h [u] [c,nc] threshold defined as and de analog r, t a ? system acpi power state 82h all system acpi power state 22h sensor specific 6fh s0 / g0 s1 s3 s4 s5 / g2 g3 mechanical off ok as ? trig offset a x button 84h all button 14h sensor specific 6fh power button reset button ok as ? trig offset a x smi timeout 85h all smi timeout f3h digital discrete 03h 01h ? state asserted critical as and de ? trig offset a ?
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 93 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby sensor failure 86h all sensor failure f6h oem sensor specific 73h i 2 c device not found i 2 c device error detected i 2 c bus timeout ok as ? trig offset a x nmi signal state 87h all oem c0h digital discrete 03h 01h ? state asserted ok ? 01h ? ? ? smi signal state 88h all oem c0h digital discrete 03h 01h ? state asserted ok ? 01h ? ? ? ierr critical thermal trip non-rec config error critical presence ok proc 1 status 90h all processor 07h sensor specific 6fh disabled degraded as and de ? trig offset m x ierr critical thermal trip non-rec config error critical presence ok proc 2 status 91h all processor 07h sensor specific 6fh disabled degraded as and de ? trig offset m x proc 1 temp 98h all temperature 01h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? proc 2 temp 9ah all temperature 01h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? bus correctable error ok pcie link0 a0h critical interrupt 13f sensor specific 6fh pcie link0 bus uncorrectable error degraded as ? see the bios eps a ?
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 94 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby bus correctable error ok pcie link1 a1h critical interrupt 13f sensor specific 6fh pcie link1 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link2 a2h critical interrupt 13f sensor specific 6fh pcie link2 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link3 a3h critical interrupt 13f sensor specific 6fh pcie link3 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link4 a4h critical interrupt 13f sensor specific 6fh pcie link4 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link5 a5h critical interrupt 13f sensor specific 6fh pcie link5 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link6 a6h critical interrupt 13f sensor specific 6fh pcie link6 bus uncorrectable error degraded as ? see the bios eps a ? pcie link7 a7h critical interrupt sensor specific pcie link7 bus correctable error ok as ? see the bios eps a ?
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 95 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby 13f 6fh bus uncorrectable error degraded bus correctable error ok pcie link8 a8h critical interrupt 13f sensor specific 6fh pcie link8 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link9 a9h critical interrupt 13f sensor specific 6fh pcie link9 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link10 aah critical interrupt 13f sensor specific 6fh pcie link10 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link11 abh critical interrupt 13f sensor specific 6fh pcie link11 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link12 ach critical interrupt 13f sensor specific 6fh pcie link12 bus uncorrectable error degraded as ? see the bios eps a ? bus correctable error ok pcie link13 adh critical interrupt 13f sensor specific 6fh pcie link13 bus uncorrectable error degraded as ? see the bios eps a ?
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 96 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby proc 1 thermal control c0h all temperature 01h threshold 01h [u] [c,nc] threshold defined as and de analog trig offset m ? proc 2 thermal control c1h all temperature 01h threshold 01h [u] [c,nc] threshold defined as and de analog trig offset m ? proc 1 vrd over temp c8h all temperature 01h digital discrete 05h 01h ? limit exceeded non-critical as and de ? trig offset m ? proc 2 vrd over temp c9h all temperature 01h digital discrete 05h 01h ? limit exceeded non-critical as and de ? trig offset m ? proc 1 vcc d0h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? proc 2 vcc d1h all voltage 02h threshold 01h [u,l] [c,nc] threshold defined as and de analog r, t a ? proc 1 vcc out-of- range d2h all voltage 02h digital discrete 05h 01h ? limit exceeded non-critical as and de discrete r, t a ? proc 2 vcc out- of-range d3h all voltage 02h digital discrete 05h 01h ? limit exceeded non-critical as and de discrete r, t a ? cpu population error d8h all processor 07h generic 03h 01h ?- state asserted critical as and de ? r, t a ? fault status asserted degraded device installed ok disabled degraded dimm a1 e0h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? dimm a2 e1h all slot connector sensor specific fault status asserted degraded as ? trig offset a ?
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 97 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby device installed ok disabled degraded 21h 6fh sparing ok fault status asserted degraded device installed ok disabled degraded dimm b1 e2h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? fault status asserted degraded device installed ok disabled degraded dimm b2 e3h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? fault status asserted degraded device installed ok disabled degraded dimm c1 e4h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? fault status asserted degraded device installed ok disabled degraded dimm c2 e5h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? fault status asserted degraded device installed ok disabled degraded dimm d1 e6h all slot connector 21h sensor specific 6fh sparing ok as ? trig offset a ? dimm d2 e7h all slot connector sensor specific fault status asserted degraded as ? trig offset a ?
appendix b: sensor tables intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 98 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby device installed ok disabled degraded 21h 6fh sparing ok memory a error ech all memory 0ch sensor specific 6fh correctable ecc uncorrectable ecc ok as ? trig offset a ? memory b error edh system- specific memory 0ch sensor specific 6fh correctable ecc uncorrectable ecc ok as ? trig offset a ? memory c error eeh system- specific memory 0ch sensor specific 6fh correctable ecc uncorrectable ecc ok as ? trig offset a ? memory d error efh system- specific memory 0ch sensor specific 6fh correctable ecc uncorrectable ecc ok as ? trig offset a ? b0 dimm sparing enabled f0h all entity presence 25h sensor specific 6fh entity present ok as ? trig offset a ? fully redundant ok non-red: suff res from redund non-red: suff res from insuff res degraded b0 dimm sparing redun- dancy f1h all memory 0ch discrete 0bh non-red: insuff res critical as ? trig offset a ? b1 dimm sparing enabled f2h all entity presence 25h sensor specific 6fh entity present ok as ? trig offset a ?
intel ? server board s5000pal / s5000xal tps appendix b: sensor tables revision 1.7 intel order number: D31979-010 99 sensor name sensor number system applica- bility sensor type event / reading type event offset triggers criticality assert / de-assert readable value / offsets event data rearm standby fully redundant ok non-red: suff res from redund non-red: suff res from insuff res degraded b1 dimm sparing redun- dancy f3h all memory 0ch discrete 0bh non-red: insuff res critical as ? trig offset a ? b01 dimm mirroring enabled f4h all entity presence 25h sensor specific 6fh entity present ok as ? trig offset a ? fully redundant ok non-red:suff res from redund non-red:suff res from insuff res degraded b01 dimm mirroring redun- dancy f5h all memory 0ch discrete 0bh non-red: insuff res critical as ? trig offset a ? note 1: not supported except for esb-2 embedded nics
appendix c: post code diagnostic leds intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 100 appendix c: post code diagnostic led decoder during the system boot process, bios executes a number of platform configuration processes, each of which is assigned a specific hex post code number. as each configuration routine is started, bios will display the given post code to the post code diagnostic leds found on the back edge of the server board. to assist in troubleshooting a system hang during the post process, the diagnostic leds can be used to identify the last post process to be executed. each post code will be represente d by a combination of colors fr om the four leds. the leds are capable of displaying three colors: green, red, and amber. the post codes are divided into two nibbles, an upper nibble and a lower nibble. each bit in the upper nibble is represented by a red led and each bit in the lower nibble is represented by a green led. if both bits are set in the upper and lower nibbles then both red and green leds are lit, resulting in an amber color. if both bits are clear, then the led is off. in the below example, bios sends a value of ach to the diagnostic led decoder. the leds are decoded as follows: ? red bits = 1010b = ah ? green bits = 1100b = ch since the red bits correspond to the upper nibble and the green bits correspond to the lower nibble, the two are concatenated to be ach. table 44: post progress code led example 8h 4h 2h 1h leds red green red green red green red green ach 1 1 0 1 1 0 0 0 result amber green red off msb lsb figure 28. diagnostic led placement diagram lsb msb diagnostic leds back edge of baseboard usb port usb port
intel ? server board s5000pal / s5000xal tps appendix c: post code diagnostic leds revision 1.7 intel order number: D31979-010 101 table 45. diagnostic led post code decoder diagnostic led decoder g=green, r=red, a=amber checkpoint msb lsb description host processor 0x10h off off off r power-on initialization of the host processor (bootstrap processor) 0x11h off off off a host processor cache initialization (including ap) 0x12h off off g r starting application processor initialization 0x13h off off g a smm initialization chipset 0x21h off off r g initializing a chipset component memory 0x22h off off a off reading configurat ion data from memory (spd on dimm) 0x23h off off a g detecting presence of memory 0x24h off g r off programming timing par ameters in the memory controller 0x25h off g r g configuring memory parameters in the memory controller 0x26h off g a off optimizing memory controller settings 0x27h off g a g initializing memory, such as ecc init 0x28h g off r off testing memory pci bus 0x50h off r off r enumerating pci busses 0x51h off r off a allocating resources to pci busses 0x52h off r g r hot plug pci controller initialization 0x53h off r g a reserved for pci bus 0x54h off a off r reserved for pci bus 0x55h off a off a reserved for pci bus 0x56h off a g r reserved for pci bus 0x57h off a g a reserved for pci bus usb 0x58h g r off r resetting usb bus 0x59h g r off a reserved for usb devices ata / atapi / sata 0x5ah g r g r resetting pata / sata bus and all devices 0x5bh g r g a reserved for ata smbus 0x5ch g a off r resetting smbus 0x5dh g a off a reserved for smbus local console 0x70h off r r r resetting the video controller (vga) 0x71h off r r a disabling the video controller (vga) 0x72h off r a r enabling the video controller (vga) remote console 0x78h g r r r resetting the console controller 0x79h g r r a disabling the console controller 0x7ah g r a r enabling the console controller keyboard (ps2 or usb) 0x90h r off off r resetting the keyboard 0x91h r off off a disabling the keyboard
appendix c: post code diagnostic leds intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 102 diagnostic led decoder g=green, r=red, a=amber checkpoint msb lsb description 0x92h r off g r detecting the presence of the keyboard 0x93h r off g a enabling the keyboard 0x94h r g off r clearing keyboard input buffer 0x95h r g off a instructing keyboard controller to run self test (ps2 only) mouse (ps2 or usb) 0x98h a off off r resetting the mouse 0x99h a off off a detecting the mouse 0x9ah a off g r detecting the presence of mouse 0x9bh a off g a enabling the mouse fixed media 0xb0h r off r r resetting fixed media device 0xb1h r off r a disabling fixed media device 0xb2h r off a r detecting presence of a fixed media device (ide hard drive detection, etc.) 0xb3h r off a a enabling / configuring a fixed media device removable media 0xb8h a off r r resetting removable media device 0xb9h a off r a disabling removable media device 0xbah a off a r detecting presence of a removable media device (ide cdrom detection, etc.) 0xbch a g r r enabling / configuring a removable media device boot device selection 0xd0 r r off r trying boot device selection 0xd1 r r off a trying boot device selection 0xd2 r r g r trying boot device selection 0xd3 r r g a trying boot device selection 0xd4 r a off r trying boot device selection 0xd5 r a off a trying boot device selection 0xd6 r a g r trying boot device selection 0xd7 r a g a trying boot device selection 0xd8 a r off r trying boot device selection 0xd9 a r off a trying boot device selection 0xda a r g r trying boot device selection 0xdb a r g a trying boot device selection 0xdc a a off r trying boot device selection 0xde a a g r trying boot device selection 0xdf a a g a trying boot device selection pre-efi initialization (pei) core 0xe0h r r r off started dispatching early initialization modules (peim) 0xe2h r r a off initial memory found, configured, and installed correctly 0xe1h r r r g reserved for initialization module use (peim) 0xe3h r r a g reserved for initialization module use (peim) driver execution environment (dxe) core 0xe4h r a r off entered efi driver execution phase (dxe) 0xe5h r a r g started dispatching drivers 0xe6h r a a off started connecting drivers dxe drivers
intel ? server board s5000pal / s5000xal tps appendix c: post code diagnostic leds revision 1.7 intel order number: D31979-010 103 diagnostic led decoder g=green, r=red, a=amber checkpoint msb lsb description 0xe7h r a a g waiting for user input 0xe8h a r r off checking password 0xe9h a r r g entering bios setup 0xeah a r a off flash update 0xeeh a a a off calling int 19. one beep unless silent boot is enabled. 0xefh a a a g unrecoverable boot failure / s3 resume failure runtime phase / efi operating system boot 0xf4h r a r r entering sleep state 0xf5h r a r a exiting sleep state 0xf8h a r r r operating system has requested efi to close boot services (exitbootservices ( ) has been called) 0xf9h a r r a operating system has switc hed to virtual address mode (setvirtualaddressmap ( ) has been called) 0xfah a r a r operating system has requested the system to reset (resetsystem () has been called) pre-efi initialization module (peim) / recovery 0x30h off off r r crisis recovery has been initiated because of a user request 0x31h off off r a crisis recovery has been initiated by software (corrupt flash) 0x34h off g r r loading crisis recovery capsule 0x35h off g r a handing off control to the crisis recovery capsule 0x3fh g g a a unable to complete crisis recovery.
appendix d: post error messages and handling intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 104 appendix d: post error messages and handling whenever possible, the bios will ou tput the current boot progress co des on the video screen. progress codes are 32-bit quantities plus optional data. the 32-bit numbers include class, subclass, and operation information. the class and subclass fields point to the type of hardware that is being initialized. the operation field represents the specific initialization ac tivity. based on th e data bit availability to display progress codes, a progress code can be customized to fit the data width. the higher the data bit, the higher the granularity of information that can be sent on the progress port. the progress codes may be reported by the system bios or option roms. the response section in the following table is divided into two types: pause: the message is displayed in the error manager screen, an error is logged to the sel, and user input is required to conti nue. the user can take immediate corrective action or choose to continue booting. halt: the message is displayed in the error manager screen, an error is logged to the sel, and the system cannot boot unless the error is resolved. the user needs to replace the faulty part and restart the system. table 46. post error messages and handling error code error message response 004c keyboard / interface error pause 0012 cmos date / time not set pause 5220 configuration cleared by jumper pause 5221 passwords cleared by jumper pause 5223 configuration default loaded pause 0048 password check failed halt 0141 pci resource conflict pause 0146 insufficient memory to shadow pci rom pause 8110 processor 01 internal error (ierr) on last boot pause 8111 processor 02 internal error (ierr) on last boot pause 8120 processor 01 thermal trip error on last boot pause 8121 processor 02 thermal trip error on last boot pause 8130 processor 01 disabled pause 8131 processor 02 disabled pause 8160 processor 01 unable to apply bios update pause 8161 processor 02 unable to apply bios update pause 8190 watchdog timer failed on last boot pause 8198 operating system boot watchdog timer expired on last boot pause 0192 l3 cache size mismatch halt 0194 cpuid, processor family are different halt 0195 front side bus mismatch pause 0197 processor speeds mismatched pause 8300 baseboard management controller failed self-test pause 8306 front panel controller locked pause 8305 hot swap controller failed pause 84f2 baseboard management controller failed to respond pause 84f3 baseboard management controller in update mode pause 84f4 sensor data record empty pause
intel ? server board s5000pal / s5000xal tps appendix d: post error messages and handling revision 1.7 intel order number: D31979-010 105 error code error message response 84ff system event log full pause 8500 memory component could not be configured in the selected ras mode. pause 8520 dimm_a1 failed self test (bist). pause 8521 dimm_a2 failed self test (bist). pause 8522 dimm_a3 failed self test (bist). pause 8523 dimm_a4 failed self test (bist). pause 8524 dimm_b1 failed self test (bist). pause 8525 dimm_b2 failed self test (bist). pause 8526 dimm_b3 failed self test (bist). pause 8527 dimm_b4 failed self test (bist). pause 8528 dimm_c1 failed self test (bist). pause 8529 dimm_c2 failed self test (bist). pause 852a dimm_c3 failed self test (bist). pause 852b dimm_c4 failed self test (bist). pause 852c dimm_d1 failed self test (bist). pause 852d dimm_d2 failed self test (bist). pause 852e dimm_d3 failed self test (bist). pause 852f dimm_d4 failed self test (bist). pause 8540 memory component lost redundancy during the last boot. pause 8580 dimm_a1 correctable ecc error encountered. pause 8581 dimm_a2 correctable ecc error encountered. pause 8582 dimm_a3 correctable ecc error encountered. pause 8583 dimm_a4 correctable ecc error encountered. pause 8584 dimm_b1 correctable ecc error encountered. pause 8585 dimm_b2 correctable ecc error encountered. pause 8586 dimm_b3 correctable ecc error encountered. pause 8587 dimm_b4 correctable ecc error encountered. pause 8588 dimm_c1 correctable ecc error encountered. pause 8589 dimm_c2 correctable ecc error encountered. pause 858a dimm_c3 correctable ecc error encountered. pause 858b dimm_c4 correctable ecc error encountered. pause 858c dimm_d1 correctable ecc error encountered. pause 858d dimm_d2 correctable ecc error encountered. pause 858e dimm_d3 correctable ecc error encountered. pause 858f dimm_d4 correctable ecc error encountered. pause 8600 primary and secondary bios ids do not match. pause 8601 override jumper is set to force boot from lower alternate bios bank of flash rom pause 8602 watchdog timer expired (secondary bios may be bad!) pause 8603 secondary bios checksum fail pause
appendix d: post error messages and handling intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 106 post error beep codes the following table lists post error beep codes. prior to system video initialization, bios uses these beep codes to inform users on error conditions. the beep code is followed by a user visible code on post progress leds. table 47. post error beep codes beeps error message post progress code description 3 memory error system halted because a fatal error related to the memory was detected. 6 bios rolling back error the system has detected a co rrupted bios in the flash part, and is rolling back to the last good bios. the bmc may generate beep codes upon detection of failure conditions. beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. codes that are common across all intel ? server boards and systems that use the intel ? s5000 chipset are listed in table 48. each digit in the code is represented by a sequence of beeps whose count is equal to the digit. table 48. bmc beep codes code reason for beep associated sensors supported? 1-5-2-1 cpu: empty slot / population error ? processor slot 1 is not populated. cpu population error yes 1-5-2-2 cpu: no processors (terminators only) n/a no 1-5-2-3 cpu: configuration erro r (e.g., vid mismatch) n/a no 1-5-2-4 cpu: configuration error (e.g., bsel mismatch) n/a no 1-5-4-2 power fault: dc power unexpectedly lost (power good dropout) power unit ? power unit failure offset yes 1-5-4-3 chipset control failure n/a no 1-5-4-4 power control fault power unit ? soft power control failure offset yes
intel ? server board s5000pal / s5000xal tps appendix e: supported intel ? server chassis revision 1.7 intel order number: D31979-010 107 appendix e: supported intel ? server chassis the intel? server board s5000pal / s5000xal is supported in the following intel high density rack mount server chassis: ? intel ? server chassis sr1500 ? intel ? server chassis sr1550 ? intel ? server chassis sr2500 this section provides a high level descriptive overview of each chassis. for more detail, please reference the appropriate technical product specification (tps) available for each. tp02154 a b e c d f h i j k l a o n m g p a rack handles i pci card bracket (low profile) ? pcie* b backplane ? passive sas/sata or active sas/sas raid j processor air duct c air baffle k fan module d power supply fans l bridge board e 600 watt power supply m control panel (standard control panel shown) f intel? server board s5000pal / s5000xal n hard drive bays (drives not included) g pci card bracket (full height) ? pci-x* or pcie* o slimline drive bay (drive not included) h pci add-in riser assembly p front bezel (optional) figure 29. 1u ? intel ? server chassis sr1500 overview
appendix e: supported intel ? server chassis intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 108 a rack handles l riser card assembly b sas/sata backplane m system memory c sas raid battery pack (optional) n processor and heat sink d power supply air duct o processor air duct e power distribution board p system fan bank f 1+1 650 watt power supply modules q mid-plane board (active - sas/sas raid shown) g intel? server board s5000pal / s5000xal r front bezel (optional; standard control panel shown) h bridge board s standard control panel or intel ? local control panel (optional) i intel ? rmm module (optional) t mini control panel bay ? required option to support eight hard drives j intel ? rmm nic(optional) u slimline optical drive bay k io module (optional) v up to eight 2.5? hard drive bays figure 30. 1u ? intel ? server chassis sr1550 overview
intel ? server board s5000pal / s5000xal tps appendix e: supported intel ? server chassis revision 1.7 intel order number: D31979-010 109 tp02094 a b d c e f g h i a l k j m n a. rack handles h. cpu air duct b. sas/sata backplane i. system fan assembly c. air baffles j. standard control panel d. power distribution module k. flex bay ? 6 th hdd or tape (optional) e. 1+1 750 watt power supply modules l. five sata/sas hard drive bays f. riser card assembly m. slim-line optical drive bay g. system memory n. front bezel (optional) mid-pane ? passive sas/sata or active sas/sas raid (not shown) figure 31. 2u ? intel ? server chassis sr2500 overview
glossary intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 110 glossary this appendix contains important terms used in the preceding chapters. for ease of use, numeric entries are listed first (e.g., ?82460gx?) with alpha entries following (e.g., ?agp 4x?). acronyms are then entered in their respective place, with non-acronyms following. term definition acpi advanced configuration and power interface ap application processor apic advanced programmable interrupt control asic application specific integrated circuit asmi advanced server management interface bios basic input/output system bist built-in self test bmc baseboard management controller bridge circuitry connecting one computer bus to anot her, allowing an agent on one to access the other bsp bootstrap processor byte 8-bit quantity. cbc chassis bridge controller (a microcontroller c onnected to one or more other cbcs, together they bridge the ipmb buses of multiple chassis. cek common enabling kit chap challenge handshake authentication protocol cmos in terms of this specification, this describes the pc-at compatible region of battery-backed 128 bytes of memory, which normally resides on the server board. dpc direct platform control eeprom electrically erasable programmable read-only memory ehci enhanced host controller interface emp emergency management port eps external product specification esb-2 enterprise south bridge 2 fbd fully buffered dimm fmb flexible mother board frb fault resilient booting fru field replaceable unit fsb front side bus gb 1024mb gpio general purpose i/o gtl gunning transceiver logic hsc hot-swap controller hz hertz (1 cycle/second) i2c inter-integrated circuit bus ia intel ? architecture ibf input buffer ich i/o controller hub icmb intelligent chassis management bus ierr internal error ifb i/o and firmware bridge intr interrupt ip internet protocol ipmb intelligent platform management bus
intel ? server board s5000pal / s5000xal tps glossary revision 1.7 intel order number: D31979-010 111 term definition ipmi intelligent platform management interface ir infrared itp in-target probe kb 1024 bytes kcs keyboard controller style lan local area network lcd liquid crystal display led light emitting diode lpc low pin count lun logical unit number mac media access control mb 1024kb mch memory controller hub md2 message digest 2 ? hashing algorithm md5 message digest 5 ? hashing algorithm ? higher security ms milliseconds mttr memory type range register mux multiplexor nic network interface controller nmi nonmaskable interrupt obf output buffer oem original equipm ent manufacturer ohm unit of electrical resistance pef platform event filtering pep platform event paging pia platform information area (this feature config ures the firmware for the platform hardware) pld programmable logic device pmi platform management interrupt post power-on self test psmi power supply management interface pwm pulse-width modulation ram random access memory rasum reliability, availability, serviceability, usability, and manageability risc reduced instruction set computing rom read only memory rtc real-time clock (component of ich peripheral chip on the server board) sdr sensor data record secc single edge connector cartridge seeprom serial electrically erasable programmable read-only memory sel system event log sio server input/output smi server management interrupt (smi is the highest priority nonmaskable interrupt) smm server management mode sms server management software snmp simple network management protocol tbd to be determined tim thermal interface material uart universal asynchronous receiver/transmitter
glossary intel ? server board s5000pal / s5000xal tps revision 1.7 intel order number: D31979-010 112 term definition udp user datagram protocol uhci universal host controller interface utc universal time coordinate vid voltage identification vrd voltage regulator down word 16-bit quantity zif zero insertion force
intel ? server board s5000pal / s5000xal tps reference documents revision 1.7 intel order number: D31979-010 113 reference documents see the following documents for additional information: ? intel ? s5000 series chipsets server board family datasheet ? intel ? s5000 server board family bios core external product specification (yellow cover) ? intel ? s5000 server board family bmc core external product specification (yellow cover) ? intel ? 5000p memory controller hub external design specification (yellow cover) ? intel ? enterprise south bridge-2 (esb-2) external design specification (yellow cover) ? teb 2.11 ? thin electronics bay (1u/2u rack optimized) ? eps 1u rev. 2.93 ? entry level power supply ? 1u non-redundant ? intel ? s5000 server board family ? erp 2u ? rev. 2.31 ? entry redundant power supply 2u form factor ? intel ? s5000 server board family note: yellow cover documents can only be obtained under nda with intel and ordered through an intel representative.


▲Up To Search▲   

 
Price & Availability of D31979-010

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X